2OM-1751-003w_G5S - 第108页
2OM-1751 1-56 1303-001 Continuation 2 The system keeps on saving the data when the component data has the same ID and is not used. (Continuation 2) (Before Changeover) 101 AAA 102 BBB 103 C C C 104 D D D (After Changeove…

2OM-1751
1-551303-001
4.2.9 Data
When the [Data] button is pressed on the "Opr. Mode" tab sheet, the following
window appears.
[2]
[1]
F2A36
[1] Temp Comp Lib Save Mode
One of the following options can be selected for saving the carrier data.
[Standard] Button
When selected, the data saving operation continues only when the component
data is perfectly consistent.
(Standard)
(Before Changeover)
101 AAA
102 BBB
103 CCC
104 DDD
(After Changeover)
All are initialized because there is a
difference in 102.
101 AAA
102 DDD
103 CCC
104 DDD
Initialized
Initialized
Initialized
Initialized
Simplified Packaging
Direction Change Function
F2A37
[Continuation 1] Button
The system keeps on saving only the component data that has the same ID.
(Continuation 1)
(Before Changeover)
101 AAA
102 BBB
103 CCC
104 DDD
(After Changeover)
The 102 data is initialized because
there is a difference.
The 104 data is cleared because
it is not used.
The other data is continued.
101 AAA
102 DDD
103 CCC
104
Continued
Initialized
Continued
Cleared
Simplified Packaging
Direction Change Function
F2A38
4.2 "Opr.Mode" Tab Sheet

2OM-1751
1-561303-001
Continuation 2
The system keeps on saving the data when the component data has the same
ID and is not used.
(Continuation 2)
(Before Changeover)
101 AAA
102 BBB
103 CCC
104 DDD
(After Changeover)
The 102 data is initialized because
there is a difference.
The 104 data is sustained because
it is not used.
The other data is continued.
101 AAA
102 DDD
103 CCC
104
Continued
Initialized
Continued
Continued
Edited Data
F2A39
[2] Temp Comp Lib Edit Mode
The changing method for the edited data is selected in this text box.
Standard
The edited data is maintained.
Comp Lib Priority
When selected, this button initializes the pieces of data having the changed
IDs to be those in the component library data.
4.2 "Opr.Mode" Tab Sheet

2OM-1751
1-571303-001
4.2.10 Noz Blow
This function is used to prevent the nozzle clogging.
Using this function can extend the nozzle maintenance interval.
When the [Noz Blow] button is pressed on the "Opr. Mode" tab sheet, the
following window appears.
[2]
[1]
[4]
[3]
[5]
F2A40
[1] Head 1, Head 2
Disable
When this button is selected, the nozzle air blowing function is not activated.
Enable
When this button is selected, the nozzle air blowing function is activated.
[2] Effective only under "WAIT"
Disable
The nozzle air blowing function is used during the Machine (STANDBY)
mode.
Enable
The nozzle air blowing function is used based on the set timing.
Graphic
Development
4.2 "Opr.Mode" Tab Sheet