2OM-1751-003w_G5S - 第111页
2OM-1751 1-59 1303-001 4.2.1 1 Flux spread When the [Flux spread] button is pressed on the "Opr. Mode" tab sheet, the following window appears. F2A41 It is set when the ux application unit (option) is used. 4.…

2OM-1751
1-581303-001
[3] Execution Timing
Specify the timing to execute the air blowing.
Operation time
Select this button to specify the timing of the execution based on the running
time.
PCB Count
Select this button to specify the timing of the execution based on the number
of PCBs.
[4] Count
The set value is designated based on the item selected in executive timing.
When the [Run Time] is selected, the interval from the automatic operation
start to the air blow execution is set based on time.
When the [PCB Counter] is selected, the interval from the automatic
operation start to the air blow execution is set based on the completed
number of PCBs.
[5] [Blow Count] Button
Specify the number of blowing times.
4.2 "Opr.Mode" Tab Sheet

2OM-1751
1-591303-001
4.2.11 Flux spread
When the [Flux spread] button is pressed on the "Opr. Mode" tab sheet, the
following window appears.
F2A41
It is set when the ux application unit (option) is used.
4.2 "Opr.Mode" Tab Sheet

2OM-1751
1-601303-001
4.2.12 Multi Head
When the [Multi Head] button is pressed on the "Opr. Mode" tab sheet, the
following window appears.
[1] [2]
F2A42
[1] Simultaneous pick
The multi-functional head is used when the nozzle pitch of head agrees with
the tape feeder pitch for component pickup.
Enable
: When selected, the component simultaneous pickup is performed.
Disable
: When selected, the component simultaneous pickup is not
performed.
[2] Multi Nzl ID check befor RUN
Enable
: When selected, the ID of the nozzle housed in the nozzle stocker
for the multi-functional nozzle, is identied and the data is re-
written in the case that the identication result is not the same as
that on the placement nozzle/head data.
Also, it is checked whether if all the nozzles required for the
production, have been prepared.
Disable
: When selected, the nozzle ID recognition function is not used.
4.2 "Opr.Mode" Tab Sheet