2OM-1751 2-9 1303-001 Items Ref. No. DN MOVE 1st speed DCLR SET 2nd speed DCLR SET V ac. Ctrl. delayed starts V ac. Wtg. Timer Dama ged V ac. Wtg. time Backup axis DN start DL Y D02_10 T2B1 1 D03 Transfer Speed Data Item…

100%1 / 380
2OM-1751
2-81303-001
2.4 Composition of Control Data
The set parameters are used to set the automatic operation and PCB transfer
control.
Reference
Refer to "3.4 Control" in Chapter 2, for the details of each item.
D01 Control Data
Items Ref. No.
Placement Mode D01_01
PCB Finishing Position D01_02
Pre-PL cmpnt thkns
PCB Top [mm], PCB Bottom [mm]
D01_03
PEC expansion correction D01_04
T2B9
D02 PCB Locate Data
Items Ref. No.
PCB detection off DLY D02_01
PCB Locate SET D02_02
PCB Locate Sequence D02_03
UP
MOVE
1st Speed DCLR SET
2nd Speed DCLR SET
Z Clamp
Opr. waiting time
Opr. ST DLY timer
D02_04
DN
MOVE
1st Speed DCLR SET
2nd Speed DCLR SET
Backup axis DN start DLY
D02_05
SW POSN of 1st / 2nd D02_06
Replace vacuum sensor D02_07
PCB position of contact D02_08
UP
MOVE
1st speed DCLR SET
2nd speed DCLR SET
Vac. Ctrl. delayed starts
Vac. Wtg. Timer
Z clamp waiting time
D02_09
T2B10
2.4 Composition of Control Data
2OM-1751
2-91303-001
Items Ref. No.
DN
MOVE
1st speed DCLR SET
2nd speed DCLR SET
Vac. Ctrl. delayed starts
Vac. Wtg. Timer
Dama ged Vac. Wtg. time
Backup axis DN start DLY
D02_10
T2B11
D03 Transfer Speed Data
Items Ref. No.
Transportation speed SET D03_01
Transfer speed
Carrier, Stage inside, Output
D03_02
Input CNVR Y POSN ARR spd set-up D03_03
Output CNVR Y POSN ARR spd set-up D03_04
Component Deviation Control
Carrier, Stage inside, Output
D03_05
Control the stop position
Carrier, Positioning 1, Positioning 2, Output
D03_06
T2B12
2.4 Composition of Control Data
2OM-1751
2-101303-001
2.5 Composition of Placement Nozzle Data
The set parameters are used to place the nozzles onto the specied positions on
the head (Place Head/Noz No.).
Reference
Refer to "3.5 PL Head / Nozzle" for the details of each item according to the
reference Nos. (Ref. Nos.).
E01 Nozzle Place Data
Items Ref. No.
Nozzle Place (E01)
Nozzle Stk 1 (E02)
Nozzle Stk 2 (E02)
T2B13
2.6 Composition of Placement Feeder Location Data
The set parameters are used to determine which feeder slot Nos. (Fdr No.) various
types of components should be allocated to.
Component IDs (types of components to be allocated) must be specied for each
individual feeder bases.
Reference
Refer to "3.6 CMPNT PL" for the details of each item according to the reference
Nos. (Ref. Nos.).
F01 CMPNT PL Data
Items Ref. No.
Fdr No. (F01_01)
Component ID (F01_02)
C (Control Command) (F01_03)
Comment (F01_04)
Feeder Fixed (F01_05)
Feeder Alternate (F01_06)
Fdr No. (F01_07)
Component Library Comment (F01_08)
Dir [deg], Carrier Data Type, Width [mm] (F01_09)
Fd. Pitch [mm] (F01_10)
Used Parts (F01_11)
Nozzle Type (F01_12)
T2B14
2.5 Composition of Placement Nozzle Data