2OM-1751-003w_G5S - 第132页

2OM-1751 2-10 1303-001 2.5 Composition of Placement Nozzle Data The set parameters are used to place the nozzles onto the specied positions on the head (Place Head/Noz No.). Reference Refer to "3.5 PL Head / Nozzle…

100%1 / 380
2OM-1751
2-91303-001
Items Ref. No.
DN
MOVE
1st speed DCLR SET
2nd speed DCLR SET
Vac. Ctrl. delayed starts
Vac. Wtg. Timer
Dama ged Vac. Wtg. time
Backup axis DN start DLY
D02_10
T2B11
D03 Transfer Speed Data
Items Ref. No.
Transportation speed SET D03_01
Transfer speed
Carrier, Stage inside, Output
D03_02
Input CNVR Y POSN ARR spd set-up D03_03
Output CNVR Y POSN ARR spd set-up D03_04
Component Deviation Control
Carrier, Stage inside, Output
D03_05
Control the stop position
Carrier, Positioning 1, Positioning 2, Output
D03_06
T2B12
2.4 Composition of Control Data
2OM-1751
2-101303-001
2.5 Composition of Placement Nozzle Data
The set parameters are used to place the nozzles onto the specied positions on
the head (Place Head/Noz No.).
Reference
Refer to "3.5 PL Head / Nozzle" for the details of each item according to the
reference Nos. (Ref. Nos.).
E01 Nozzle Place Data
Items Ref. No.
Nozzle Place (E01)
Nozzle Stk 1 (E02)
Nozzle Stk 2 (E02)
T2B13
2.6 Composition of Placement Feeder Location Data
The set parameters are used to determine which feeder slot Nos. (Fdr No.) various
types of components should be allocated to.
Component IDs (types of components to be allocated) must be specied for each
individual feeder bases.
Reference
Refer to "3.6 CMPNT PL" for the details of each item according to the reference
Nos. (Ref. Nos.).
F01 CMPNT PL Data
Items Ref. No.
Fdr No. (F01_01)
Component ID (F01_02)
C (Control Command) (F01_03)
Comment (F01_04)
Feeder Fixed (F01_05)
Feeder Alternate (F01_06)
Fdr No. (F01_07)
Component Library Comment (F01_08)
Dir [deg], Carrier Data Type, Width [mm] (F01_09)
Fd. Pitch [mm] (F01_10)
Used Parts (F01_11)
Nozzle Type (F01_12)
T2B14
2.5 Composition of Placement Nozzle Data
2OM-1751
2-111303-001
2.7 Composition of Placement Data
The set parameters are used to place the components (IDs in the placement feeder
location data) on the points with the specied coordinates in the designated
direction.
One step is allocated for each component to be placed.
Reference
Refer to "3.7 Placement Data" for the details of each item.
Items Ref. No.
Un (G01)
Offset Data (G02)
Offset (G02)
Unit Control (G02_01)
Offset
X [mm], Y [mm], Z [ ° ], H [mm]
(G02_02)
Unit PCB Fiducial (G02_03)
Recog Coord
X1, Y1, X2, Y2
(G02_04)
Fiducial Mark
FM1, FM2
(G02_05)
D-Data (G03)
P-Data (G03)
PNo. (G03_01)
X [mm], Y[mm] (G03_02)
Z [ ° ] (G03_03)
H [mm] (G03_04)
Component ID (G03_05)
Fdr. No. (G03_06)
Symbol (G03_07)
C (G03_08)
Comment (G03_09)
ADJ X,Y (G03_10)
O-Data (G04)
Ono. (G04_01)
X [mm], Y[mm] (G04_02)
Z [ ° ] (G04_03)
H [mm] (G04_04)
C (G04_05)
Comment (G04_06)
B-X, B-Y (G04_07)
T2B15
2.7 Composition of Placement Data