2OM-1751 2-42 1303-001 1st speed DCLR SET The backup base operation speed reduction rate is set in this text box. This value is reected on the rst operation in the 2-stage operation in the PCB positioning, and second o…

100%1 / 380
2OM-1751
2-411303-001
(D02_01)
PCB detection off DLY
The time period from the PEC recognition to PCB release is set in this text
box.
(D02_02)
PCB locate SET
Common :
When selected, the PCB positioning is set commonly to the
machines in the line.
Individual :
When selected, the PCB positioning is set individually for each
machine in the line.
(D02_03)
PCB locate Sequence
The PCB positioning mode is set in this text box.
Backup Base + Z Clamp
: When selected, the positioning is performed
using the backup base and the Z-clamp.
Z Clamp
: When selected, the positioning is performed
only using the Z-clamp.
PCB vacuum support
: When selected, the positioning is performed
using the vacuum jig.
(D02_04)
UP
Positioning 1, Positioning 2
MOVE
The PCB moving up operation for positioning is selected from "Standard" or
"Value Set".
Normally, "Standard" is selected.
Standard
:
When selected, the PCB is moved up for positioning
based on the standard value set in the machine.
Low Speed 1
:
When selected, the operation speed is one step lower
than the standard value.
Low Speed 2
:
When selected, the operation speed is two step lower
than the standard value.
Low Speed 3
:
When selected, the operation speed is three step lower
than the standard value.
Low Speed 4
:
When selected, the operation speed is four step lower
than the standard value.
Value Set
: When selected, the speed value can be set freely.
3.4 Control
2OM-1751
2-421303-001
1st speed DCLR SET
The backup base operation speed reduction rate is set in this text box.
This value is reected on the rst operation in the 2-stage operation in the
PCB positioning, and second operation in the 2-stage operation in the PCB
releasing.
2nd speed DCLR SET
The backup base operation speed reduction rate is set in this text box.
This value is reected on the second operation in the 2-stage operation in
the PCB positioning, and rst operation in the 2-stage operation in the PCB
releasing.
Z Clamp
Opr. waiting time
The Z-clamp operation WAIT time is set in this text box.
Opr. ST DLY timer
The time period from the backup base moving up start to Z-clamp moving
up start, is set in this text box.
(D02_05)
DN
Positioning 1, Positioning 2
MOVE
The PCB moving down operation for positioning is selected from "Standard"
or "Value Set".
Normally, "Standard" is selected.
Standard
:
When selected, the PCB is moved up for positioning
based on the standard value set in the machine.
Low Speed 1
:
When selected, the operation speed is one step lower
than the standard value.
Low Speed 2
:
When selected, the operation speed is two step lower
than the standard value.
Low Speed 3
:
When selected, the operation speed is three step lower
than the standard value.
Low Speed 4
When selected, the operation speed is four step lower
than the standard value.
Value Set : W
hen selected, the speed value can be set freely.
1st speed DCLR SET
The backup base operation speed reduction rate is set in this text box.
This value is reected on the rst operation in the 2-stage operation in the
PCB positioning, and second operation in the 2-stage operation in the PCB
releasing.
3.4 Control
2OM-1751
2-43
2nd speed DCLR SET
The backup base operation speed reduction rate is set in this text box.
This value is reected on the second operation in the 2-stage operation in
the PCB positioning, and rst operation in the 2-stage operation in the PCB
releasing.
Backup axis DN start DLY
The time period for the Z-clamp releasing operation completion after the
component placement completion, is set in this text box. After this operation
is completed, the backup base starts moving down.
(D02_06)
SW POSN of 1st / 2nd
The change position between the "First Speed" and "Second Speed" is set in
this data box.
(D02_07)
Replace vacuum sensor
The sensor to be used for vacuum pick-up is selected in this data box.
This function is used when the vacuum judgment threshold value is to be
changed.
Sensor #1
: When selected, the vacuum pick-up is performed using the
sensor #1.
Sensor #2
: When selected, the vacuum pick-up is performed using the
sensor #2.
(D02_08)
PCB position of contact
The offset from the transfer position (moving up rst stage/moving down
rst stage target position) is setup. The value for carrier thickness, etc., is
input as upper direction value (plus value).
(D02_09)
UP
MOVE
"Standard" or "Value Designation" is selected for the PCB positioning
moving up operation.
Normally, "Standard" is selected.
Standard
: The operation is performed based on the standard
values set in the machine.
Value Designation
: For the operation procedure, the selected values
can be setup.