2OM-1751-003w_G5S - 第170页
2OM-1751 2-48 1303-001 (D03_05) Avoid comp deviation Carrier , Stage inside, Output The following items are set for "Reload", "Stage Inside" and "Discharge". Speed 1 [mm/sec] The PCB is tran…

2OM-1751
2-471303-001
(D03_01)
Transportation speed SET
Common :
When selected, the transfer speed is set commonly to the
machines in the line.
Individual :
When selected, the transfer speed is set individually for each
machine in the line.
(D03_02)
Transfer speed
Carrier, Stage inside, Output
Select the PCB transfer speed from the following items.
Std(Max)
: When selected, the PCB is transferred at the standard speed.
-20%
: When selected, the PCB is transferred at the speed 20%
lower than the standard.
-40%
: When selected, the PCB is transferred at the speed 40%
lower than the standard.
-60%
: When selected, the PCB is transferred at the speed 60%
lower than the standard.
-80%
: When selected, the PCB is transferred at the speed 80%
lower than the standard.
Value Set
: When selected, any speed level is set freely for the PCB
transfer.
(D03_03)
Input CNVR Y POSN ARR spd set-up
Setup the input conveyor Y-position arrangement speed reduction rate.
(D03_04)
Output CNVR Y POSN ARR spd set-up
Setup the output conveyor Y-position arrangement speed reduction rate.
3.4 Control

2OM-1751
2-481303-001
(D03_05)
Avoid comp deviation
Carrier, Stage inside, Output
The following items are set for "Reload", "Stage Inside" and "Discharge".
Speed 1 [mm/sec]
The PCB is transferred at the specied speed.
Speed 2 [mm/sec]
The PCB transferred at the Speed 1, is detected using the speed reduction
sensor and the speed is reduced to the "Speed 2"specied here in this text
box.
Acceleration [G]
The acceleration to reach the speed specied in "Speed 1"is set in this text
box.
(D03_06)
Stop position control
Carrier, Positioning 1, Positioning 2, Output
The following items are set for "Reload", "Positioning 1", "Center",
"Positioning 2"and "Discharge".
Timer [msec]
The time period for the PCB detected using the speed reduction sensor, to
reach the reduced speed specied in "Speed 2", is set in this text box.
•
Initial Value:350 [msec]
Position [mm]
The distance from the position of the PCB detected using the stop sensor
to the PCB stop position, is set in this text box.
3.4 Control

2OM-1751
2-491303-001
3.5 PL Head/Nozzle
(E01) Nozzle Place Data
When the [Nozzle Place] tab is pressed in the "PL Head/Nozzle" window,
the following tab sheet appears.
F2B40
(E01_01) Nozzle Place
Head1 and 2
Nozzle No. 1 to 15
This data is used to allocate the nozzles to the specied positions (Nozzle
Allocation Nos.) on the heads.
Graphic
Development
3.5 PL Head/Nozzle