2OM-1751-003w_G5S - 第173页
2OM-1751 2-51 1303-001 3.6 CMPNT PL (F01) CMPNT PL Data When the [Block 1] or [Block 2] tab is pressed on the "CMPNT PL Data" window, the following tab sheet appears. F2B42 (F01_01) Fdr No. Shown are the feeder…

2OM-1751
2-50
(E02) Nozzle Stk 1, 2 data
When the [Nozzle Stk 1] or [Nozzle Stk 2] tab is pressed on the "PL Head/
Nozzle" window, the following tab sheet appears.
F2B41
(E02_01) Nozzle Stk 1, 2
Address Stk Types 1 to 15
Using these parameters, the nozzles are housed in the specied positions
(address stocker type) in the nozzle stocker.
High
: 1 to 15
Multi
: 1 to 9
1303-001
3.5 PL Head/Nozzle
Graphic
Development

2OM-1751
2-511303-001
3.6 CMPNT PL
(F01) CMPNT PL Data
When the [Block 1] or [Block 2] tab is pressed on the "CMPNT PL Data"
window, the following tab sheet appears.
F2B42
(F01_01)
Fdr No.
Shown are the feeder Nos. in the placement feeder location data.
Block 1
: 101 to 150
Block 2
: 201 to 250
(F01_02)
Component ID
Set component IDs in the text boxes.
Graphic
Development
3.6 CMPNT PL

2OM-1751
2-521303-001
(F01_03)
C
Set control commands in the text boxes.
Notice
If a control command other than the following ones is used, the step
becomes invalid.
- (hyphen)
: This command handles the steps as those for the placement
feeder location data.
E
: This command shows the end of the placement feeder location
data. The step where "E" is set is valid.
S
: This command invalidates the steps specied as placement
feeder location data.
X
: This command invalidates the steps specied as placement
feeder location data and shows the end of the data.
(F01_04)
Comment
Set a comment for each Fdr No.Up to 32 characters (alphanumerics and
symbols) can be used. Alphanumeric characters and symbols can be used.
Note
(a) The performance of the machine is not affected by these commands.
In other words, it has nothing to do with or without these comments.
(b) It is recommended to set helpful information on components related
to the feeder Nos. (Fdr No.).
(F01_05)
Feeder Fixed
Select "Enable" or "Disable" to determine whether or not the feeder positions
should be xed in place. When "Enable" is selected, the feeder Nos.
(Fdr No.) and the component ID are not affected by any insert and delete
operations of a component.
Disable
: The feeder position is not xed.
Enable
: The feeder position is xed.
(F01_06)
Feeder Alternate
Select "Enable" or "Disable" to determine whether or not the feeder alternate
function should be used.
Disable
: The feeder alternate function is not used.
Enable
: The feeder alternate function is used.
(F01_07)
Fdr No.
When "Enable" is selected for the feeder alternate function, set the
destination feeder No. (Fdr No.) of the feeder that will work in place of the
feeder where a component pickup error has occurred in succession.
3.6 CMPNT PL