2OM-1751 2-54 3.7 Placement (G01) Placement Data [1] [2] [3] [4] F2B43 [1] T ool Bar The operation commands that can be executed in the "Placement" window, are collectively displayed as icons. Icons Description…

2OM-1751
2-531303-001
(F01_08)
Component Library Comment
Shown are the comments that were entered in the component library data.
(F01_09)
Carrier Type, Dir [deg], and Width [mm]
Shown are the values specied in the component library data.
(F01_10)
Fd. Pitch [mm]
Shown are the feed pitches specied in the component library data.
(F01_11)
Used Parts
Shown is the number of components to be used for one unit PCB.
(F01_12)
Nozzle Type
Shown is the number of components to be used for one unit PCB.
3.6 CMPNT PL

2OM-1751
2-54
3.7 Placement
(G01) Placement Data
[1]
[2]
[3]
[4]
F2B43
[1] Tool Bar
The operation commands that can be executed in the "Placement" window,
are collectively displayed as icons.
Icons Description
When pressed, the "Symbol Data" window appears.
When pressed, the selected unit is copied and deleted.
The currently displayed U-data is cut out.
When pressed, the selected unit is copied.
The currently displayed U-data is copied.
When pressed, the copied unit is inserted.
The U-data (the selected unit is copied and deleted, or the
selected unit is copied) is pasted.
When pressed, the selected unit is deleted.
The currently displayed U-data is deleted.
When pressed, new unit is added at the end.
New U-data is added to the end of the U-data.
New unit is inserted before the selected unit.
New U-data is inserted before the currently selected U-data.
The O-data is added to the selected unit.
The O-data is added to the currently selected U-data.
The O-data in the selected unit is deleted.
The O-data in the currently selected U-data is deleted.
T2B15
1303-001
3.7 Placement
Graphic
Development

2OM-1751
2-55
[2] [Edit] Button
When this button is pressed, the P-Data or O-Data is edited.
When the data to be edited is selected and the [Edit] button is pressed, the
"Data Setting" window appears.
F2B44
Reference
Refer to (G03) or (G04) for each item to be set.
[3] Placement Data Group Select Button
Using this button, the placement data group is selected.
[4] Placement Data Select Button
Using this button, the placement data is selected.
1303-001
3.7 Placement