2OM-1751-003w_G5S - 第218页

2OM-1751 4-4 1303-001 2.1 "Mach.Prfrm," T ab Sheet When the [Mach.Prfrm,] tab is pressed in the "MNG.DT." window, the following tab sheet appears inside the window. [1] [2] [3] [4] [5] [6] [7] [8] [9]…

100%1 / 380
2OM-1751
4-31303-001
[3] Information on Totalization File
This eld displays "Clear Date" and "Comment".
[Comment] Button
When this button is pressed, the "String Key" window appears. In this
window, the comment for "Type #1" or "Type #2" can be input.
[4] [Type #1] and [Type #2] Button
This icon displays the "Type #1" or "Type #2" window.
2. "MNG.DT." Window
2OM-1751
4-41303-001
2.1 "Mach.Prfrm," Tab Sheet
When the [Mach.Prfrm,] tab is pressed in the "MNG.DT." window, the following
tab sheet appears inside the window.
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
"Mach.Prfrm," Tab Sheet (1/5) F2D3
[1] PCB counter
Shown is the number of produced PCBs.
Counting is implemented when the X/Y table is zeroed after component
placement operation (when a PCB is nished).
Note
When a particular pattern program is set several times as current one, the
sum total is computed.
[2] Product PCB
The number of produced unit PCBs on multi-unit PCB is summed up.
Counting is implemented when the X/Y beam is zeroed after component
placement operation (when a unit is nished).
When the bad board reject (BBR) function is used, defective unit PCBs are
excluded.
[3] Passed PCB
The number of passed PCBs is counted when the machine is set in the
"PASS" mode.
Counting is implemented when the PCB transfer starts (when the PCB on the
PCB positioning section is transferred to the output conveyor).
[4] Product PCB (BBR)
Shown is the number of defective PCBs summed up when the bad board
reject function (option) is used.
2.1 "Mach.Prfrm," Tab Sheet
2OM-1751
4-51303-001
[5] Total components
Shown is the number of picked components (the number of pickup
operations).
[6] Total handling errors (A+B+G+L)
Shown is the total number of component handling errors.
[7] Rate of handling errors(%)
Shown is the percentage of handling errors per total number of picked
components.
[8] Shortage of component
Shown is the total number of detected component shortage errors.
[9] Waste components
Shown is the total number of components that were picked up but not placed.
Note
The indicated number of components represents the components that
were not placed due to a vertical component error (sensor), a component
recognition error, a component thickness error, interrupted production, the
detection (Unit PCB BBR Mode: Option) of a defective unit PCB., etc.
[10] Warm-up run(Test Md)
The data of the warm-up run (dry cycle) is counted.
PCB counter
The number of PCBs is counted when the machine is operated under the
following condition.
"TEST PATTERN" is enabled in the "Test Mode" window.
The "PCB Transfer Dsbl." check box is checked
(State in which no PCB is put in and out)
Not Picked Counts
The number of non-handling/non-placed actions is counted when the
machine is operated under the following condition.
"TEST PATTERN" is enabled in the "Test Mode" window.
The "Handling/Place Disabled" or the "Vacuum/Blower Disabled" check
box is ticked.
Note
The number of non-handling and placement actions is counted although
the X/Y beam takes running actions.
2.1 "Mach.Prfrm," Tab Sheet