2OM-1751-003w_G5S - 第226页

2OM-1751 4-12 1303-001 2.2 "FdrMng." T ab Sheet [1] [2] [3] [4] [5] [6] [7] [8] [9] "FdrMng." Tab Sheet (1/2) F2D8 [10] [11] [12] [13] [14] [18] [15] [16] [17] "FdrMng." Tab Sheet (2/2) F2D9…

100%1 / 380
2OM-1751
4-111303-001
3pt err (% of Total PEC Recog. err)
Shown are the total number of errors detected on the third ducial mark and
the percentage of the detected errors per total number of all errors detected
by the PEC recognition function.
[16] Lcl
d.err (% of Total PEC recog. err)
Shown are the total number of recognition errors in each individual
components and the percentage of the detected errors per total number of all
errors detected by the PEC recognition function.
[17] Total PEC recognition errors
Shown is the total number of errors detected by the PEC recognition
function.
The number of errors detected by the global PEC recognition function and
the total number of errors detected by the BBR recognition function are
displayed
2.1 "Mach.Prfrm," Tab Sheet
2OM-1751
4-121303-001
2.2 "FdrMng." Tab Sheet
[1] [2] [3] [4] [5] [6] [7] [8] [9]
"FdrMng." Tab Sheet (1/2) F2D8
[10] [11] [12] [13] [14]
[18]
[15] [16] [17]
"FdrMng." Tab Sheet (2/2) F2D9
Note
(a) The displayed tab sheet will look different, depending on which option is
selected.
(b) Each item box functions as a button and each pressing of the buttons can
list the data parameters in descending order. The top box shows the largest
value for error times. Therefore, it is useful for the analysis to enhance the
operation rate. When the [Feeder No.] button is pressed, the Nos. are re-
arranged in their initial order (Feeder Nos.).
The "FdrMng." tab sheet is divided further into several tabs and each tab sheet
shows the handling errors per feeder on each individual feeder bases.
When each tab is pressed, the corresponding tab sheet appears.
2.2 "FdrMng." Tab Sheet
2OM-1751
4-131303-001
[1] Feeder No.
Shown are the feeder Nos.
[2] Total Noz. Usage
Each text box shows the number of pickup actions for each individual
nozzles.
[3] Total Hdlg Errors
The No. of total error times in the pick-up operation is displayed in this data
box.
[4] Rate of Hdlg Err (%)
The percentage of the pick-up error total times to the pick-up total times, is
displayed in this data box.
[5] Total Errors
Each text box shows the total number of errors detected in [7] through [16].
[6] Rate of Error (%)
Each text box shows the percentage of the total number of errors per the
number of picked components.
[7] A:Comp. Missing
Each text box shows the total number of missing components detected by the
linear measure detection sensor for each individual feeders.
[8] B:Comp. Missing
Each text box shows the total number of missing components detected
through recognition operation for each individual feeders.
[9] C:Comp. Vertical
Each text box shows the total number of vertical component errors detected
by the linear measure detection sensor for each individual feeders.
[10] D:Comp. Recog.
Each text box shows the total number of errors detected through recognition
operation for each individual feeders.
[11] E:Comp. Thick
Each text box shows the total number of errors in component thickness
detected by the linear measure detection sensor for each individual feeders.
[12] F:Pick-up Diff
Each text box shows the total times of pick-up deviation in each feeder in the
recognition processing.
2.2 "FdrMng." Tab Sheet