2OM-1751-003w_G5S - 第242页

2OM-1751 4-28 1303-001 T otal errors Shown is the total number of component handling errors. [16] "Mach.Prfrm," Tab Sheet (4/5) F2D18 [16] "Mach.Prfrm," Tab Sheet (5/5) F2D19 [16] Zones #1 to #5 1pt e…

100%1 / 380
2OM-1751
4-271303-001
B:comp. missing (% of Total err)
Shown are the number of component missing errors detected in the
recognition process and the percentage of component missing errors per total
number of pickup errors.
C:comp. vertical (% of Total err)
Shown are the number of vertical component errors detected by the linear
measure detection sensor and the percentage of vertical component errors per
total number of pickup errors.
D:comp. recog (% of Total err)
Shown are the number of errors detected in the recognition process and the
percentage of errors per total number of pickup errors.
E:comp. thick (% of Total err)
Shown is the percentage of component thickness errors detected by the linear
measure detection sensor per total number of pickup errors.
F:pick-up diff. (% of Total err)
Shown are the number of pickup difference errors detected in the recognition
process and the percentage of the errors per total number of pickup errors.
G:comp. posture (% of Total err)
Shown are the number of reversed component and polarity judgment errors
detected in the recognition process and the percentage of the errors per total
number of pickup errors.
H:measur. err (% of Total err)
Shown is the percentage of measurement error times based on the total error
times.
K:coplanarity (% of Total err)
Shown is the error detected while the optional unit is being attached.
L:obverse / reverse (% of Total err)
The percentage of the error times in the front/rear judgment using the linear
measure to the pick-up error total times, is displayed in this data box.
3.2 "Mach.Prfrm," Tab Sheet
2OM-1751
4-281303-001
Total errors
Shown is the total number of component handling errors.
[16]
"Mach.Prfrm," Tab Sheet (4/5) F2D18
[16]
"Mach.Prfrm," Tab Sheet (5/5) F2D19
[16] Zones #1 to #5
1pt err (% of Total PEC Recog. err)
Shown are the total number of errors detected on the rst ducial mark and
the percentage of the detected errors per total number of all errors detected
by the PEC recognition function.
2pt err (% of Total PEC Recog. err)
Shown are the total number of errors detected on the second ducial mark
and the percentage of the detected errors per total number of all errors
detected by the PEC recognition function.
3.2 "Mach.Prfrm," Tab Sheet
2OM-1751
4-291303-001
3pt err (% of Total PEC Recog. err)
Shown are the total number of errors detected on the third ducial mark and
the percentage of the detected errors per total number of all errors detected
by the PEC recognition function.
Lcl
d.err (% of Total PEC recog. err)
Shown are the total number of recognition errors in each unit PCB and the
percentage of the detected errors per total number of all errors detected by
the PEC recognition function.
Total PEC recognition errors
Shown is the total number of errors detected by the PEC recognition
function.
The number of errors detected by the global PEC recognition function and
the total number of errors detected by the BBR recognition function are
displayed.
3.2 "Mach.Prfrm," Tab Sheet