2OM-1751-003w_G5S - 第253页
2OM-1751 4-39 1303-001 4.2 "Nozzle Message Rate" T ab Sheet [1 1] L:Obv/Reverse The "judged front/rear error" times for each nozzle, detected using the linear measure, is displayed in these data boxes…

2OM-1751
4-381303-001
The "Nozzle Message Rate" tab sheet is divided further into two tab sheets and
each tab sheet shows the nozzle management data for each individual head.
When each head selection button is pressed, the tab sheet for the corresponding
head appears.
[1] Nozzle No.
Shown are the nozzle Nos.
[2] A:Comp. Missing
Each text box shows the number of missing components detected by the
linear measure detection sensor for each individual nozzles.
[3] B:Comp. Missing
Each text box shows the number of missing components detected through
recognition operation for each individual nozzles.
[4] C:Comp. Vertical
Each text box shows the number of vertical component errors detected by the
linear measure detection sensor for each individual nozzles.
[5] D:Comp. Recog.
Each text box shows the number of errors detected through recognition
operation for each individual nozzles.
[6] E:Comp. Thick
Each text box shows the number of errors in component thickness detected
by the linear measure detection sensor for each individual nozzles.
[7] F:Pick-up Diff
Each text box shows the number of pickup difference errors detected in the
recognition process for each individual nozzles.
[8] G:Comp. Posture
Each text box shows the number of reversed component and polarity
judgment errors detected in the recognition process for each individual
nozzles.
[9] H:Meas. Error
The No. of measurement error total times for each nozzle feeder is displayed
in this data box.
[10] K:Copla. Error
The times of error decided in the coplanarity error detection is shown in this
data box.
4.2 "Nozzle Message Rate" Tab Sheet

2OM-1751
4-391303-001
4.2 "Nozzle Message Rate" Tab Sheet
[11] L:Obv/Reverse
The "judged front/rear error" times for each nozzle, detected using the linear
measure, is displayed in these data boxes.
[12] Nozzle Message Rate
(Total Errors / Total Noz. Usage)
Each text box shows the rate of pickup errors (the number of pickup errors
per number of picked component) for each individual feeders.

2OM-1751
4-401303-001