(11) Edit the parameters in the stock area image display section so that the setup
condition is the same as that for the support pins in the stock area.
Note
When the setup operation is stopped due to an error, press the [Clear]
button to clear the arrangement data for the PCB support pins on the
backup stage.
(12) Press the [Apply] button.
(The "Conrm" window will be displayed).
(13) Press the [OK] button.
(The editing operation will be ended).
F2F19
Note
When any error occurs, the PCB support pins should be re-setup.
Perform the procedure from Step (3).
F2F20
4.2 "Stkr.Area Edit" Window
2OM-1751
6-191303-001
5. "NOZ.CHG." Window
For the nozzle change, the "Overall Setup" or "Manual Setup" operation is
performed.
Note
The window shows the condition where a multi-functional head is mounted onto
the head No. 1 position.
[1]
[2]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
[11]
[3] [3][2]
F2F21
[1] "Nozzle Stocker Status Indicator" Panel
Indicated is the status of the nozzle stockers.
The background color of the "Bypassed"-specied address turns yellow.
[2] "Vacuum Nozzle Status Indicator" Field
Indicated is the status of the nozzles attached to each head.
[3] Head Selection Buttons
Press the [#1], the [#2], the [#3] or the [#4] buttons to select the head for
which some nozzles should be changed.
The background color of the selected button turns pea green.
[4] Nozzle Operation Buttons
The following buttons are provided.
When the [START] button on the operation panel is pressed in 10 seconds
after the button corresponding to the required operation is selected and the
[Move] button is pressed, the machine performs the selected operation for
the nozzle.
Graphic
Development
5. "NOZ.CHG." Window
2OM-1751
6-201303-001
[Change] Button
When pressed, this button attaches the vacuum nozzle to the placement head.
Note
When the vacuum nozzles (to be used after a program change operation)
are prepared in the extended stocker (option), they are stored and attached
in succession.
[Reset] Button
When pressed, this button stores the vacuum nozzle in the object nozzle
stocker.
[5] [Move] Button
When the [START] button on the operation panel is pressed in 10 seconds
after the button corresponding to the required operation is selected and this
button is pressed, the machine performs the selected operation for the nozzle.
Note
When the nozzle quantity is not enough in this operation, the required
nozzles are displayed in the "Nozzle Check" window.
Reference
Refer to "3. "PP CHANGE" window" in "Chapter 6" for how to use the
"Nozzle Check" window.
[6] [Zero] Button
When pressed, all devices are zeroed.
[7] [PLACE. HEAD/NOZ.] Button
Using this button, the head/nozzle placement data set in the pattern program
can be read and reected on the setup.
[Noz Stkr Place] Tab
When the button of the nozzle stocker of which arrangement data is
rewritten, is pressed and then, the [SET] button is pressed, the parameters are
rewritten.
When the [Noz Stkr Place] tab is pressed, the following tab sheet appears.
5. "NOZ.CHG." Window