2OM-1751-003w_G5S - 第297页

2OM-1751 6-25 1303-001 [5] [PCB Mem. Info.] Button In the case that PCB presence/absence does not agree with the memory due to the removal of the PCB, the PCB presence/absence data can be setup using the window operation…

100%1 / 380
2OM-1751
6-241303-001
6. "PCB XFER" Window
6.1 "Local" Tab Sheet
Using this function, the PCB on each block on the conveyor can be moved to the
next block.
[3]
[4]
[1]
[2]
[5]
F2F28
[1] Local/Line Switch Button
This button switches the "Local" tab sheet and "Line" tab sheet.
[2] [MNL XFER] Button
When pressed, the PCB positioning is performed manually.
[3] Transfer Buttons
Each block in the graphic image of the conveyor is provided with a button
function.
When the [START] button on the operation panel is pressed in 10 seconds
after a conveyor block button, the PCB is transferred to the block position.
[4] PCB LOCATE (PCB LOCATE L, R)
The PCB locating operation is performed.
When the [START] button on the operation panel is pressed in 10 seconds
after the [Execute] button, the backup base of the selected stage moves up
and the PCB is positioned.
When the [START] button on the operation panel is pressed in 10 seconds
after the [Release] button, the backup base moves down and the PCB
positioning is released.
Graphic
Development
6. "PCB XFER" Window
2OM-1751
6-251303-001
[5] [PCB Mem. Info.] Button
In the case that PCB presence/absence does not agree with the memory due
to the removal of the PCB, the PCB presence/absence data can be setup
using the window operation.
F2F29
Light Blue
: PCB Presence Status
Gray
: PCB Absence Status
6.1 "Local" Tab Sheet
2OM-1751
6-261303-001
6.2 "Line" Tab Sheet
This tab sheet enables the operator to transfer a PCB between two or more
machines.
[1]
F2F30
[1] Conveyor Image Display Section
Each block of the conveyor of which an image is displayed, functions as a
button.
When the conveyor block button is pressed and within 10 seconds, the
[START] button on the operation panel is pressed, the PCB is transferred to
the position.
Note
(a) This button is displayed when two or more machines are installed in the
line.
(b) Up to 16 conveyor blocks are displayed.
6.2 "Line" Tab Sheet