2OM-1751-003w_G5S - 第359页

2OM-1751 6-87 7.3.7.3 BGA/CSP Components Note The descriptions in this manual are based on a component whose electrode type is "Simple (electrodes arranged in equal pitches)". Procedure (1) Select [Area Array] …

100%1 / 380
2OM-1751
6-86
(10) When the teaching is completed, press the [Complete] button.
F2F96
1303-001
7.3 "COMP RCG" Test Window
2OM-1751
6-87
7.3.7.3 BGA/CSP Components
Note
The descriptions in this manual are based on a component whose electrode type
is "Simple (electrodes arranged in equal pitches)".
Procedure
(1) Select [Area Array] and [Simple] in this order and select the type of the
electrodes.
F2F97
F2F98
1303-001
7.3 "COMP RCG" Test Window
2OM-1751
6-88
Note
In the case of BGA/CSP component where the following electrodes are
arranged with uneven pitches, select [Complex].
F2F99
Notice
When "Simple" is selected as a form of electrodes, it is impossible
to perform a teaching operation on the BGA/CSP components that
are used as electrodes and arranged in unequal pitches.
F2F100
(2) Conrm that the component is in the yellow circle (frame).
When it is in the circle, press the [Yes] button. Otherwise, press the [No]
button.
F2F101
1303-001
7.3 "COMP RCG" Test Window