2OM-1751-003w_G5S - 第367页

2OM-1751 6-95 1303-001 7.4 "PEC RCG" T est Window This window enables the operator to perform the PEC recognition mark recognition test. [1] [2] [3] [4] [5] [6] [7] [9] [10] [8] [11] F2F113 [1] [Select block] B…

100%1 / 380
2OM-1751
6-94
7.3.8 Exiting from Library Data Teaching Operation
When the [Complete] button is pressed in the "Create Teach" wizard, the
"COMPONENT LIBRARY" (teaching operation) window appears again.
(1/2) F2F111
(2/2) F2F112
Pressing the [Recog] button can execute the recognition test for the created
component library data.
Pressing the [Edit] button can re-edit the created component library data.
When the teaching is to be ended, after pressing the [Dscd] or [Collect.] button to
discard or collect the component, press the [Return] button.
The data saving conrming dialog is displayed.
When the created component library data is to be saved in the test library, press
the [Yes] button and when it is to be discard, press the [No] button.
1303-001
7.3 "COMP RCG" Test Window
2OM-1751
6-951303-001
7.4 "PEC RCG" Test Window
This window enables the operator to perform the PEC recognition mark
recognition test.
[1]
[2]
[3] [4]
[5]
[6]
[7]
[9] [10]
[8]
[11]
F2F113
[1] [Select block] Button
The buttons showing each block are displayed using images. Using one of
these buttons, the block used for the PEC recognition test is selected.
[2] [Crnt. PP. Set Data] Button
When this button is pressed, the [Set Data (Crnt. PP.)] window appears.
F2F114
When [Zone n] is selected for the "Zone Choice" for the global recognition
position and the [#n] button is selected and then the [OK] button is pressed,
the position data and PEC recognition mark code are set.
The set data is displayed in the Mark Pos X, Y data boxes in the "Setup Pos
Move" window and "Recognized Data Setting" window.
Graphic
Development
7.4 "PEC RCG" Test Window
2OM-1751
6-961303-001
[3] [Mark Pos Edit] Button
Using this button, the PEC recognition mark position is setup.
Each item is shows as a button and when each button is pressed, the
corresponding data set window appears.
F2F115
Note
(a) When the pattern program has been setup, the parameters for the [PEC Size
X[mm]], [PEC Size Y[mm]] and [Y arrange Pos] are automatically set.
(b) When the settings have been performed in the "Cmt PP Data Setting"
window, the [Mrk Pos X[mm]] and [Mark Pos Y[mm]] also have already
been setup.
[4] [Mark Data Edit] Button
Press each button to set the PEC recognition mark.
F2F116
Note
When the settings have been performed in the "Cmt PP Data Setting"
window, the PEC recognition mark data has already been setup.
7.4 "PEC RCG" Test Window