2OM-1751 6-96 1303-001 [3] [Mark Pos Edit] Button Using this button, the PEC recognition mark position is setup. Each item is shows as a button and when each button is pressed, the corresponding data set window appears. …

100%1 / 380
2OM-1751
6-951303-001
7.4 "PEC RCG" Test Window
This window enables the operator to perform the PEC recognition mark
recognition test.
[1]
[2]
[3] [4]
[5]
[6]
[7]
[9] [10]
[8]
[11]
F2F113
[1] [Select block] Button
The buttons showing each block are displayed using images. Using one of
these buttons, the block used for the PEC recognition test is selected.
[2] [Crnt. PP. Set Data] Button
When this button is pressed, the [Set Data (Crnt. PP.)] window appears.
F2F114
When [Zone n] is selected for the "Zone Choice" for the global recognition
position and the [#n] button is selected and then the [OK] button is pressed,
the position data and PEC recognition mark code are set.
The set data is displayed in the Mark Pos X, Y data boxes in the "Setup Pos
Move" window and "Recognized Data Setting" window.
Graphic
Development
7.4 "PEC RCG" Test Window
2OM-1751
6-961303-001
[3] [Mark Pos Edit] Button
Using this button, the PEC recognition mark position is setup.
Each item is shows as a button and when each button is pressed, the
corresponding data set window appears.
F2F115
Note
(a) When the pattern program has been setup, the parameters for the [PEC Size
X[mm]], [PEC Size Y[mm]] and [Y arrange Pos] are automatically set.
(b) When the settings have been performed in the "Cmt PP Data Setting"
window, the [Mrk Pos X[mm]] and [Mark Pos Y[mm]] also have already
been setup.
[4] [Mark Data Edit] Button
Press each button to set the PEC recognition mark.
F2F116
Note
When the settings have been performed in the "Cmt PP Data Setting"
window, the PEC recognition mark data has already been setup.
7.4 "PEC RCG" Test Window
2OM-1751
6-971303-001
[5] [Move] Button
Using this button, the beam is moved to the set position.
[6] [Manual Alignment] Button
Using this button, the window where the recognition position setup using the
manual alignment operation, is opened.
[7] [PEC Recog] Button
When this button is pressed, the PEC recognition test is prepared.
[8] Result:
In this pane, the PEC recognition test results are displayed.
[9] [PCB XFER] Button
When this button is pressed, the "PCB Transfer" window appears.
[10] [Save Image] Button
When this button is pressed, the "Image Save" window appears.
This window is used to save the test results.
[11] [Re-Recognition] Button
After pressing this button, the recognition image is touched in the "Manual
Alignment" window to re-recognize the marks.
7.4 "PEC RCG" Test Window