2OM-1751-003w_G5S - 第61页

2OM-1751 1-9 1303-001 2.1 Local Window [5] Stop Mode [All PCB out] Button After the PCB in the course of the production, has been produced, the PCB is discharged and the automatic production operation is stopped. [Cycle]…

100%1 / 380
2OM-1751
1-81303-001
2.1 Local Window
Component Handling Rate Data
The data of the feeder where the pick-up rate has been dropped, is displayed.
"
Component Handling Rate Data
"
Window F2A8
PCB completion cycle
Max. 500 items of the measured nishing interval (interval between the
previous PCB and the current PCB at the nal step completion) are displayed
from the newest.
Note
(a) Because the interval cannot be measured before the second PCB is
completed, "---" is displayed at the rst PCB nished time.
(b) In the case that the placement status becomes "Stopping" or "Pause",
the measurement of the PCB is stopped and "---" is displayed.
(c) The history is automatically saved in "D:\mdata\MachDt\PcbInt.csy"
when the whole status becomes "Stopping".
"PCB completion cycle" Window F2A9
2OM-1751
1-91303-001
2.1 Local Window
[5] Stop Mode
[All PCB out] Button
After the PCB in the course of the production, has been produced, the PCB is
discharged and the automatic production operation is stopped.
[Cycle] Button
When the component placement operations on the PCBs in the course of
the production in each of the stage 1 and stage 2, have been completed, the
automatic production operation is stopped.
2OM-1751
1-10
2.2 Line Window
This window enables the operator to check the production line operation status
and operate the line.
In this window, the operation status of the SIGMA series machines (including
the printer) set in the line conguration, PCB transfer unit graphic image and
production data are displayed.
[1]
[6]
[5]
[7]
[3]
[4]
[5]
[2]
F2A10
[1] Local / Line Change Buttons
Using these buttons, the Local window is changed to or from the Line
window.
[2] No.
In this area, the machine Nos. in the line are displayed.
[3] Operation Status
In this area, the operation status of each machine in the line, is displayed.
RUN
: This machine is under operation.
STOP
: This machine is shut down.
PAUSE
: This machine is stopped temporarily.
[4] PCB transfer section
In this area, the operation status of each machine in the line, is displayed.
Green
: PCB present
Gray
: PCB absent
[5] Feeder Base Unit
In this area, the presence or absence of the feeder base is displayed.
Graphic
Development
1303-001
2.2 Line Window