2OM-1751-003w_G5S - 第76页
2OM-1751 1-24 Description of "Any step designation" Window When the [Any step designation] button is pressed in the "Semi-Auto Step Any Desig" W indow , the following window appears. [1] [2] [3] [4] […

2OM-1751
1-231303-001
•
Description of Semi-Auto Step Any Desig (free designation)
Two or more steps can be designated.
Description of "Semi-Auto Step Any Desig" Window
When the [Semi-Auto Step Any Desig] button is pressed in the "Start Mode"
group box, the following window appears.
[1]
[2]
[3]
[4]
F2A19
[1] No. of Total Steps and Designated Step Count Display Section
The No. of total steps and No. of designated steps are displayed in this
section.
[2] [Any step designation] Button
When this button is pressed, the "Any Step Designation" Window appears.
[3] [Start] Button
When this button is pressed, the designated step operation is started.
[4] [Placement Step Clear] Button
When this button is pressed, the placement step operation designated in the
"Any Step Designation" mode, is cleared.
4.1 "Run Mode" Tab Sheet

2OM-1751
1-24
Description of "Any step designation" Window
When the [Any step designation] button is pressed in the "Semi-Auto Step Any
Desig" Window, the following window appears.
[1]
[2]
[3] [4]
[5]
[6]
F2A20
[1] No. of Total Steps and Designated Step Count Display Section
The No. of total steps and No. of designated steps are displayed in this
section.
[2] Step Display Section
The total No. of steps in the pattern program set in the machine, is displayed.
Setting the cursor on the step item in the list, designates the step. The
background color changes as follows.
Blue
:
This shows the moved step, which has not been designated.
Yellow
:
This shows the step, which has already been designated.
Green
:
This shows the step, which has been last designated.
Note
In normal cases, the starting step Nos. are displayed in the order of actual
component placement.
By pressing the [O] or the [P] button, the steps can be re-arranged in the
ascending order.
Even when the step Nos. are rearranged, the component placement order is
not changed.
[3] [Desig.Step] Button
The step No. can be entered and designate in the entry window displayed by
pressing the [Desig Step] button.
Enter the step No. in the order of "U", "O" and "P".
1303-001
4.1 "Run Mode" Tab Sheet

2OM-1751
1-251303-001
4.1 "Run Mode" Tab Sheet
[4] [Release all steps] Button
When this button is pressed, all the designated steps and applied steps are
cleared.
[5] [Apply] Button
When this button is pressed, the designated step or cleared step is applied.
[Cancel] Button
When this button is pressed, the cleared step is cancelled.
[6] [Return] Button
When this button is pressed, the "Semi-Auto Any Desig" window is returned.
Starting Procedure for the Semi-Auto Step Any Desig (free designation)
Procedure
(1) Place the PCB on the position of the step operation to be
designated.
Note
Transfer and place the PCB manually onto the aimed position.
(2) Designate the step in the "Any step designation" window and press
the [Apply] button.
Note
A dialogue "Do you save the change?" will be displayed.
Select "Yes". After the selection, the No. of designated steps is
changed.
(3) Press the [Return] button to return to the "Semi-Auto Any Desig"
window.