2OM-1751-003w_G5S - 第79页
2OM-1751 1-27 1303-001 4.1.2 "Run Mode" Window ("Warm Start" Possible) When the machine is set in the "PAUSE" mode during the automatic operation, a warm start operation becomes possible and…

2OM-1751
1-261303-001
(4) When the [Start] button is selected, the designated step operation is
started.
Note
(a) Precautions during the step operation designated in "Any Step
Designation" mode.
•
The addition or deletion of step operation designated in the "Any
Step Designation" mode, is disabled. Before or after the component
placement, or after all applied steps are cancelled in the case of stop
in the course of the opeation, such addition or deletion is enabled.
•
In the case that the step designated in "Any Step Designation"
mode, is stopped in the course of the operation and the placement
is started again, the operation is started from the head of the undone
steps.
•
In the case that the operation is to be started again, after the step
designated in the "Any Step Designation" mode, is stopped in the
course of the operation and undone steps are cleared, the operation
is started from the head of the applied steps designated in "Any Step
Designation" mode.
•
Even when the PCB is discharged after the operation is stopped in
the course, the operated step data is not cleared.
(b) After all the steps are performed:
When the operation start is attempted after all the previously set steps
are performed, the component placement is not started. In order to
start the component placement, clear the previously set placement
steps.
(c) Applied Steps Clearing Procedure
Procedure
(1) Press the "Placement step clear" button in the
"Semi-Auto Any Desig" window.
(2) Press the "Release all step" button in the "Any
step designation" window and press the "Apply"
button.
(d) PCB Discharge
•
Discharge the PCB manually after all the steps designated in "Any
Step Designation" mode, are completed (including the stop in the
course of the operation).
•
Start the normal operation after the PCB discharge.
4.1 "Run Mode" Tab Sheet

2OM-1751
1-271303-001
4.1.2 "Run Mode" Window ("Warm Start" Possible)
When the machine is set in the "PAUSE" mode during the automatic operation, a
warm start operation becomes possible and the "Warm Start" window appears.
[1]
[2]
F2A21
[1] [Last Plc Pos Move] Button
When this button is pressed, the "Last Placement Point Check" window is
opened.
[2] [Cancel Warm Start] Button
When pressed, the warm start is cancelled.
Note
This button is displayed only in the window for the Supervisor, When the
Warm start has been stopped, the PCB is discharged without placing any
component in the re-start operation. Pay attention to it.
Reference
Refer to "5.3 Resumption of Production through Warm Start Procedure"
(Chapter 3 in Volume 1) for the detailed information on how to execute a
warm start operation.
4.1 "Run Mode" Tab Sheet

2OM-1751
1-281303-001
4.1.3 "Run Mode" Window in "Placement Recovery Available" Mode
"Enable" or "Disable" for the NL-axis Origin Teaching, is setup in this data box.
[1]
[2]
F2A22
[1] [Plc Pos Move] Button
When pressed, this button opens the "When the NL-axis origin teaching is
to be performed, the teaching time interval is selected from the following
items." window.
Reference
A pre-pick nozzle conrmation error will not occur when the pre-pick
nozzle conrmation function is not used.
Refer to "4.2 Opr. Mode Tab Sheet" in "Chapter 1" for how to use the pre-
pick nozzle conrmation function.
Note
When the machine is reset to its normal condition from the "ERROR"
window after a pre-pick nozzle conrmation error has occurred, the
"Placement Step Recovery" window appears automatically.
[2] [Cancel Place Rcvry] Button
When pressed, the placement recovery is cancelled.
4.1 "Run Mode" Tab Sheet