2OM-1751-003w_G5S - 第84页
2OM-1751 1-32 1303-001 [2] Recog NG When the result of recognition is abnormal, the graphics of the items for which the setting has been "ON" using the following buttons, are displayed. [Circle] Button When sel…

2OM-1751
1-311303-001
4.2.1 Recog Display
When the [Recog Display] button is pressed on the "Opr.Mode" tab sheet, the
following window appears.
In this window, the graphic display setting when the recognition results are
displayed, is performed.
[1]
[2]
F2A26
[1] Recog OK
When the result of recognition is normal, the graphics of the items for which
the setting has been "ON" using the following buttons, are displayed.
[Cross] Button
When selected, this displays a crosshair at the center of the recognized
object.
[Circle] Button
When selected, this displays a circle at the center of the recognized object.
[Outside] Button
When selected, this displays the outline of the recognized object.
[Nozzle Outside] Button
When selected, this displays the outline of the vacuum nozzle that was used
to recognize a component.
[Detect Pos] Button
When selected, this displays the detection area, detected corner or edge
position.
4.2 "Opr.Mode" Tab Sheet

2OM-1751
1-321303-001
[2] Recog NG
When the result of recognition is abnormal, the graphics of the items for
which the setting has been "ON" using the following buttons, are displayed.
[Circle] Button
When selected, this displays a circle at the center of the recognized object.
[Outside] Button
When selected, this displays the outline of the recognized object.
[Nozzle Outside] Button
When selected, this displays the outline of the vacuum nozzle that was used
to recognize a component.
[Detect Pos] Button
When selected, this displays the detection area, detected corner or edge
position.
Note
When the button corresponding to the set item, is pressed, turning ON/OFF of
the button can be performed.
Multiple items can be selected.
4.2 "Opr.Mode" Tab Sheet

2OM-1751
1-331303-001
4.2.2 Image Save
When the [Image Save] button is pressed on the "Opr. Mode" tab sheet, the
following window appears.
Set parameters in the "Object" and "Select" text boxes to analyze the cause of a
recognition error in comparison with the error image on the monitor.
When "Save" is set in the "Mode" text box, the image which matches the
parameters in the "Object" and "Select" text boxes is stored in memory of the
Machine.
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
[11]
Image Save F2A27
[1] Mode
Select one of the following options to determine whether or not the
recognized image should be saved.
Not Save
: The recognized image is not saved.
Save [Recog NG]
: The recognized image is saved only when the
recognition results in "NG" (No Good).
Save [Recog OK]
: The recognized image is saved only when the
recognition results in "OK".
Save [Recog NG/OK]
: The recognized image is saved when the
recognition results in "NG" or "OK".
Note
When "Not Save" is selected, the other items cannot be set.
4.2 "Opr.Mode" Tab Sheet