2OM-1751-003w_G5S - 第99页

2OM-1751 1-47 1303-001 [4] Fdr In/Out "Enable" or "Disable" can be selected to determine whether or not the feeder offset (B) data should be cleared automatically when the feeder is installed or unins…

100%1 / 380
2OM-1751
1-461303-001
(X) Dir
Enable
Select this button to use the automatic feeder axis adjustment function for
the X direction.
Disable
Select this button not to use the automatic feeder axis adjustment function
for the X direction.
(Y) Dir
Enable
Select this button to use the automatic feeder axis adjustment function for
the Y direction.
Disable
Select this button not to use the automatic feeder axis adjustment function
for the Y direction.
Note
(a) In normal cases, the [Enable] button should be selected.
(b) The designation of the pickup auto adjust function for a specic
feeder can be canceled in the component library data.
(c) When the machine is set in the "RUN" or the "WAIT" mode,
the data save operation (saving of changed settings) cannot be
performed.
[2] Height data in Fdr
Enable
Select this button to use the feeder height data when components are picked
up.
Disable
Select this button not to use the feeder height data when components are
picked up.
[3] Fdr Fiducial Recog
Enable
It is selected when the Feeder Fiducial Recognition is used.
Disable
It is selected when the Feeder Fiducial Recognition is not used.
4.2 "Opr.Mode" Tab Sheet
2OM-1751
1-471303-001
[4] Fdr In/Out
"Enable" or "Disable" can be selected to determine whether or not the feeder
offset (B) data should be cleared automatically when the feeder is installed
or uninstalled.
Fdr Offset (B) Auto Clear
Disable
Select this button not to clear the feeder offset (B) data automatically when
the feeder is installed or uninstalled.
Enable
Select this button to clear the feeder offset (B) data automatically when the
feeder is installed or uninstalled.
[5] Start with installed Fdr only
Disable
When pressed, automatic operation with installed feeder only is available.
Enable
When pressed, automatic operation with installed feeder only is disabled.
[6] In-use Fdr in/out
Disable
This button is selected when the "in-use feeder in/out" function is not used.
Enable
This button is selected when "in-use feeder in/out" function is used.
4.2 "Opr.Mode" Tab Sheet
2OM-1751
1-481303-001
4.2.7 Tape Pocket Recog
When the [Pocket Recognition] button is pressed on the "Operation Mode" tab
sheet, the following tab sheet appears.
This function recognizes the pocket edge section, nds the pocket center and
feedbacks the result to the feeder offset (B) value.
[6]
[2]
[3]
[4]
[5]
[8]
[9]
[10]
[11]
[7]
[1]
[12]
[13]
[15]
"Tape Rocket Recog" Tab Sheet (1/2) F2A33
[15]
[14]
"Tape Rocket Recog" Tab Sheet (2/2) F2A34
Note
(a) This function can be used for the components (size: 2012 or less) packaged
in a paper tape.
(b) In the case that the actual component size is out of the range of
±
25% of the
component size set in the component library, the "Machine Information"
window appears.
4.2 "Opr.Mode" Tab Sheet