4-16 AKBEG-ID (1 1) The ducial mark position of the feeder is measured. The following dialog box appears for three seconds. Fig. D18 (12) Move the micrometer until the hole at the ducial mark position is aligned with t…

4-15
AKBEG-ID
(10) Press the [START] button in the window.
The accuracy inspection is executed, excluding the following two
points.
•
Discrepancy in Type Data
When a discrepant item exists in the type data, a warning message box
opens, indicating that the accuracy inspection cannot be executed.
Correct the discrepant data.
•
"Lot Data Inp" Window
When "0" or "1" is set in the "Lot Data Input Omission Flag" text box
in the "Type Setting #1" window, the "Lot Data Inp" window opens
once before the inspection is executed initially, prompting you to set the
lot data.
When the [START] button is pressed after the setting, the accuracy
inspection starts.
Reference
Refer to "4. "Type Setting" Window" in "Section 3" for the lot data input omis-
sion ag.
Fig. D17 "Lot Data Inp" Window
Lot # :
"type-yyyymmdd" is automatically allocated as a le name
to be recorded. (yyyy = Year, mm = Month, dd = Day)
Example:
200
4/08/17 = 20040817
Work # :
The numerical values in the serial area of the serial No. are
automatically allocated and entered in the text box.
Ofce # :
An arbitrary string of characters can be entered.
Operator :
An arbitrary string of characters can be entered.
Comment :
An arbitrary string of characters can be entered.
0508-001
2. Feeder Measurement

4-16
AKBEG-ID
(11) The ducial mark position of the feeder is measured.
The following dialog box appears for three seconds.
Fig. D18
(12) Move the micrometer until the hole at the ducial mark position is
aligned with the center of the crosshair.
4
2
4
2
4 8
12
Direction of Tape Feed
Fiducial Mark Position of
G*-12160 or more
(G*-24320 used in the figure)
Fiducial Mark Position
of G*-0808*
Fig. D19 Position of Fiducial Mark
0809-002
2. Feeder Measurement

4-17
AKBEG-ID
The ducial mark position is based on the X/Y coordinates of the computer
screen and almost located at the coordinates in the following table.
Table D4
Models X Y
G*-0808*
-
3.650
-
13.000
G*-12160 or more
-
13.950
-
13.000
Align the hole at the
fiducial mark position
with the center of the
crosshair.
X/Y Position on
Computer Screen
Fig. D20
(13) Press the [Space] key on the keyboard or the [X/Y Measurement]
button in the window to perform the measurement of the ducial mark
position.
(14
) Then, measure the pickup position.
The following dialog box appears for three seconds.
Fig. D21
0508-001
2. Feeder Measurement