JO-072-006_w.pdf - 第104页

4-18 AKBEG-ID (15) Move the micrometer until the hole of the master tape is aligned with the center of the crosshair . As for the 8 mm feeder , it must be aligned with the pickup position on Lane #1. 8 mm T ape Feeder La…

100%1 / 137
4-17
AKBEG-ID
The ducial mark position is based on the X/Y coordinates of the computer
screen and almost located at the coordinates in the following table.
Table D4
Models X Y
G*-0808*
-
3.650
-
13.000
G*-12160 or more
-
13.950
-
13.000
Align the hole at the
fiducial mark position
with the center of the
crosshair.
X/Y Position on
Computer Screen
Fig. D20
(13) Press the [Space] key on the keyboard or the [X/Y Measurement]
button in the window to perform the measurement of the ducial mark
position.
(14
) Then, measure the pickup position.
The following dialog box appears for three seconds.
Fig. D21
0508-001
2. Feeder Measurement
4-18
AKBEG-ID
(15) Move the micrometer until the hole of the master tape is aligned with
the center of the crosshair.
As for the 8 mm feeder, it must be aligned with the pickup position on
Lane #1.
8 mm Tape Feeder
Lane #1
Lane #2
Fig. D22
The pickup position of each model is based on the X/Y coordinates of the
computer screen and almost located at the coordinates in the following
table.
Move the cursor to the position where the hole of the master tape can be
visible perfectly and perform the measurement.
As for the Y direction, the position varies by 0.5 mm (8 mm feeder) and 1
mm (12 mm or wider feeder).
Ref.:
Th
e variation occurs because the lane origin offset is set to "0" (zero)
at the measurement.
Table D5
Models X Y
G*-0808*
Lane #1 0.000 0.000
Lane #2 9.500 0.000
G*-12160 4.100
-2.00
G*-24320 -2.600 -6.000
G*-44
560 -8.600 -14
.000
0512-002
2. Feeder Measurement
4-19
AKBEG-ID
(16) Press the [Space] key on the keyboard or the [X/Y Measurement] button
in the window to perform the measurement of the pickup position.
When this operation is performed, the master tape is automatically fed
to the next pickup position after the measurement is completed.
(17) After that, align the hole of the master tape with the center of the
crosshair again.
(18) Follow the same procedure as in (16) and perform the
measurement.
(19) The measurement is repeated the specied number of times.
The defaults (measurement counts) are specied as follows.
Table D6
Models Measurement Counts
G*-0808 10 times
G*-12160 or more 9 times
In the case of "8 mm Feeder", the following message box appears after
the measurement (repeated the above-described number of times).
Subsequently, follow the same procedure to perform the measurement
for the lane #2 side.
Fig. D24
0508-001
2. Feeder Measurement