4-26 AKBEG-ID (4) Check the reading of the pry-type dial gauge. Example 1: When the dial gauge reads "-0.02 mm" as shown below , it is required to enter the of fset value "20". Fig. D33 Example 2: Whe…

4-25
AKBEG-ID
(2) Raise the suppressor and perform the measurement as shown below.
Measurement with GT-08080 (Example)
Push down the feeder
with your hand.
Fig. D30
(3) See the gures below for the spots to be measured.
•
Measuring Position for G*-0808*
Measuring Position on
Lane #2 Side
Measuring Position on
Lane #1 Side
Fig. D31
•
G*-12160 or more
Measure the area beside
the fiducial mark.
Magnified View
Fig. D32
0508-001
3.2 Measuring Method

4-26
AKBEG-ID
(4) Check the reading of the pry-type dial gauge.
Example 1:
When the dial gauge reads "-0.02 mm" as shown below, it
is required to enter the of
fset value "20".
Fig. D33
Example 2:
When the dial gauge reads "+0.03 mm" as shown bellow,
it is required to enter the of
fset value "-30".
Fig. D34
0508-001
3.2 Measuring Method

4-27
AKBEG-ID
4. Default Setting of Program for Feeder Measurement
¡
: Measurement Possible with Feeder Adjusting Jig
r
:
The data measured by the height gauge can be transferre
d to the feeder
adjusting jig.
×
: Measurement Impossible
T
able D7
0508-001
4. Default Setting of Program for Feeder Measurement