3-19 AKBEG-ID Description of Each Displayed Items [7] [6] [3] [5] [1] [2] [8] [9] [4] Fig. C16 [1] The displayed mark will be spinning while this program is running. [2] Displayed is the referential value of the sequence…

3-18
AKBEG-ID
6. "Measurement" Window
This window can be used to execute an accurate inspection of the feeder,
view the results of the inspection, and create an accuracy table.
When you press the [Meas] button located at the bottom of each window, the
"Measurement" window opens.
Description of Each Button
[5]
[6]
[3]
[4][1]
[2]
Fig. C15 "Measurement" Window
[1]
When pressed, this button starts the measurement.
While the measurement is performed, the label on the button is changed
to "ST
OP". When the [STOP] button is pressed, the measurement is
interrupted temporarily.
[2]
This represents that the measurement is interrupted.
This appears when the measurement is interrupted temporarily with the
[ST
OP] button in [1].
[3]
When pressed, this button opens the "Accuracy Measurement Table"
window.
[4]
When pressed, this button opens the "Chart" window
.
[5]
When pressed, this button opens or closes the image window
.
[6]
The current X and
Y positions are regarded as the results of each
measurement.
0508-001
6. "Measurement" Window

3-19
AKBEG-ID
Description of Each Displayed Items
[7]
[6]
[3]
[5]
[1][2]
[8][9]
[4]
Fig. C16
[1]
The displayed mark will be spinning while this program is running.
[2]
Displayed is the referential value of the sequence speed.
Ref.:
This value changes greatly according to the processed contents.
[3]
Displayed is the automatic running mode.
[RUN], [PAUSE], [ST
OP]
[4]
Displayed are the current execution mode and a message.
[5]
Displayed is the status of each signal that indicates whether or not
feeders are installed.
The box beside "Feeder 2" turns light blue (
) when the feeder is
installed.
The box beside "Feeder 1" turns light blue ( ) when the power is turned
"ON".
The box beside "MS-ON" turns light blue ( ) in the "Clamp" mode.
[6]
Displayed are the lane and pickup hole Nos. under inspection.
[7]
Displayed are the feeder parameters.
[8]
Displayed are the current X/Y
coordinates (address) of the table.
[9]
Displayed are the X/Y
coordinates (address) of the measurement
address (design value).
Type No. Type Name Serial No.
Fig. C17
0508-001
6. "Measurement" Window

3-20
AKBEG-ID
6.1 Accuracy Measurement Table
When the [Accur] button (located on the bottom of the "Measurement"
window) is pressed, the "Accuracy Measurement Table" window opens.
A list of les saved according to each serial No. are displayed in the accuracy
measurement table. Each le contains the results (those passed by the
inspection) of the feeder inspection.
By selecting an "Msd" le (Path: D:\MeasureData), the results of the
inspection can be conrmed and/or printed.
Fig. C18 Accuracy Measurement Table
0508-001
6.1 Accuracy Measurement Table