21 Zoll breite LP X Serie - 第14页

2 Retrofit instructions: 21" wide PCB (00176062-01 ) SIPLACE X-series Special Design 05/2006 Edition 14 2.5 Safety instructions W ARNING The safety instructio ns from the “Operational sa fety” chapter of the user ma…

100%1 / 22
Special Design 2 Retrofit instructions: 21" wide PCB (00176062-01) SIPLACE X-series
05/2006 Edition
13
2 Retrofit instructions:
21" wide PCB (00176062-01)
SIPLACE X-series
2.1 Description of the functions
Modified conveyor firmware combined with the LBO for X-series may be used to process PCBs
that are up to 21“ wide. The restrictions in the "Long board option“ retrofit instructions for the X-
series apply. 2
2.2 Requirements
Conveyor firmware: TB610548.HEX 2
Software: 601.x 2
Hardware: SIPLACE X-series with Long board option 2
2.3 Restrictions
Min. PCB width: 100 mm
No mapping data can be recorded within 12.5 mm of the side edge.
Automatic width adjustment is not possible
Modified variant of the LBO option for X-series.
2.4 Parts required
Retrofit kit: Long board, X-series (00119672-xx)
1 x spacer for stopper (00371915-xx)
Special design firmware TB610548.HEX
2 Retrofit instructions: 21" wide PCB (00176062-01) SIPLACE X-series Special Design
05/2006 Edition
14
2.5 Safety instructions
WARNING
The safety instructions from the “Operational safety” chapter of the user manual and servicing in-
structions take precedence over these instructions. 2
The SIPLACE placement machines are supplied with mains voltage.
Consequently parts of these systems carry dangerous voltages! This voltage is present at certain
modules inside the machine base, even when the machine is switched off at the main power
switch.
Incorrect handling of the placement machine or touching live parts of the machine can result in
death or severe injury, and considerable damage to equipment.
BEFORE starting any work, shut down the operating system correctly, then switch the machine
OFF at the main power switch and disconnect from the main power supply. In addition, the com-
pressed air supply must be switched off at the compressed air unit's main valve in the machine
base and vented by actuating the needle valve on the compressed air unit.
There is DANGER for heart pacemaker wearers in the vicinity of the linear motors, as described
in detail in the "Special safety instructions for working in the vicinity of strong magnetic fields"
section of the user manual and service manual.
Always follow the accident prevention regulations, DIN or other standards and special safety
rules applicable in your country.
Pay attention to the information concerning residual voltages in the Operational Safety chapter.
Follow the ESD regulations as described in the operational safety section of the operating
instructions.
During the retrofit, always secure the machine to prevent access by other people and to prevent
it being switched on again. The procedure is described in the “Locking the machine…” section of
the user manual.
Working with the SITEST program further increases the risk of accident.
The SITEST program must only be used by authorized and trained personnel.
2
2.5.1 Definitions
2
PLEASE NOTE 2
2
Special Design 2 Retrofit instructions: 21" wide PCB (00176062-01) SIPLACE X-series
05/2006 Edition
15
2.6 Retrofit
2.6.1 Long board option
Installation of the Long board option is described in retrofit instructions 00193888-02. 2
: Also install the stopper spacer (00371915-xx) in placement area 2 since the fixed conveyor
side wall must be set to overwide using the SITEST function.
Setting the fixed conveyor side wall to overwide makes the space for installing the additional stop-
per for the LBO in PA2 critical. 2
: For this reason, you should fit a spacer in order to ensure there is sufficient space for installa-
tion.
2
Additional spacer for stopper