2.8 Notes on the station's behavior
– The special design firmware must be downloaded using the SITEST function.
– The fixed conveyor side wall must be set to overwide using the SITEST function.
– The width must be adjusted to 21“ using the SITEST function.
– In SITEST, the PCB reference corner in PA1 and PA2 must be recalibrated.
– When the job is set on the machine, the following error message appears: "Conveyor error:
155 Conveyor belt width setting is outside the travelling range“. This error message can be
ignored.
2
Setting the fixed conveyor side wall to overwide makes the space for installing the additional stop-
per for the LBO in PA2 critical. For this reason, a spacer must be fitted in order to ensure there is
sufficient space for installation. 2
2.9 Removal
A standard firmware version must be downloaded using SITEST and the fixed conveyor side wall
must be reset to standard width. If necessary, the LBO must be removed as described in the in-
structions. 2