00198092-01_JC_PM_WF2_TX_EN - 第47页
15 WF 2 TX-Series Maintenance Check the cover fans 2 min 1 / 1 C A U T I O N ! R e f e r t o s a f e t y i n s t r u c t i o n s i n u s e r m a n u a l b e f o r e c o m m e n c i n g M a i n t e n a n c e Machine Sta…

14 WF 2 TX-Series Maintenance Calibration C&P20 P 14 min 4 / 4
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status ON Conveyor Empty
NOTICE! ESD guidelines are to be followed Tool:
T2, T4
Wear Part: Consumables:
www.asm-smt.com
19 Open covers. 20 Remove the calibration tool. 21 Remove the nozzle reject box.
22 Remove the calibration nozzles from reject
box.
23 Return the nozzle reject box. 24 Close cover.

15 WF 2 TX-Series Maintenance Check the cover fans 2 min 1 / 1
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status ON Conveyor Empty
NOTICE! ESD guidelines are to be followed Tool: Wear Part: Consumables:
www.asm-smt.com
1 Click on "maintenance" icon. 2 Click on "check fans" icon. 3 Press machine start.
4 Check results. 5 If NOT OK then contact service.

www.asm-smt.com