00195440-05-SG_D-Series_FSE-EN - 第142页
8 Gantry 8.5 Room for Your Sketches and Notes 8.4.2 Gantry Settings 142 Student Guide SIPLACE D-Series (FSE) 8.5 8 . 5 R o o m f o r Y o u r S k e t c h e s a n d N o t e s Room for Your Sketches and Notes

8 Gantry
8.4.2 Gantry Settings 8.4 Settings
Student Guide SIPLACE D-Series (FSE) 141
*
Equipment in addition to standard manual tools
8.4.2.1
8.4.2.1 Fitting the Incremental Scale
Fitting the Incremental Scale
8.4.2.2
8.4.2.2 FSE Note
FSE Note
Gantry head
distributor
DIP switch as specified for the respec-
tive gantry arrangement
'Head interface’ Currently
---
Head distribu-
tor
––– 'Gantry interface’ Currently
---
Trailing cable
distributor
––– Trailing cable in-
terface
Currently
---
Axis dynamics
X-motor (pri-
mary part)
Axis Dynamics D3 (5ms faster
than with 602)
Y-motor Axis Dynamics D3 (5ms faster
than with 602)
Y drive mag-
nets
Axis dynamics – check urgently rec-
ommended as the motor magnet
spacing or the space between the in-
dividual magnetic plates could influ-
ence the axis dynamics of the linear
drives.
D3
Assembly Tools & equip-
ment *
Setting type Comments See also
NOTICE
X incremental scale
► The X incremental scale on the D4/D4i is glued to a metal strip, which can be unscrewed.
► The X incremental scale on the D3 is to be glued onto an aluminum strip, along the stopper
edge. Before stripping off the scale, mark where it starts on the aluminum strip.
NOTICE
Art und Quelle der Gefahr
Individual gauges are available for correct positioning of all incremental scales used for the X/
Y axes. The spare parts set for the scale includes instructions for usage. This service work may
only be performed by SIPLACE service technicians.

8 Gantry
8.5 Room for Your Sketches and Notes 8.4.2 Gantry Settings
142 Student Guide SIPLACE D-Series (FSE)
8.5
8.5 Room for Your Sketches and Notes
Room for Your Sketches and Notes

8 Gantry
8.4.2 Gantry Settings 8.5 Room for Your Sketches and Notes
Student Guide SIPLACE D-Series (FSE) 143