00195440-05-SG_D-Series_FSE-EN - 第178页

9 C&P Placement Heads 9.5 Settings 9.5.2 Overview of Settings on the C&P6/12 178 Student Guide SIPLACE D-Series (FSE) Belt tension of the Z axis Belt tension measurement de - vice Belt tension 280 +/- 5 Hz Z axis…

100%1 / 290
9 C&P Placement Heads
9.5.2 Overview of Settings on the C&P6/12 9.5 Settings
Student Guide SIPLACE D-Series (FSE) 177
9.5.2
9.5.2 Overview of Settings on the C&P6/12
Overview of Settings on the C&P6/12
Connectors Description
X1, 40-pole Connected to plug X14 on the head board
Voltage supply, tacho and track signals for the Z axis drive
Signal from light barrier "Z axis in top position"
Signal from light barrier "Z axis in bottom position" (sensor stop signal)
Control signal for the air blast valve
Supply voltage +5 VDC, ±15 VDC
Reference point signal for the DP axis
Track signals for the DP axis
X2, 40-pole Connected to plug X13 of the gantry head distributor
Voltage supply and track signals for the star axis drive
Reference point for the star axis
Analog air blast pressure value
Supply voltages +5 VDC, ±15 VDC, +24 VDC
X3, 10-pole Connection for the Z motor and Z tacho signal (tacho signal is not used on
the HF machine)
X4, 10-pole Connection for the Z axis track signals
X5, 10-pole Connection for the star motor
X6, 6-pole Connection for the air blast valve
X7, 10-pole Connection for the DP axis track signals
X10, 10-pole Connection for the "Z axis up" signal
X11, 8-pole Connection for the light barrier "Z axis down" signal (sensor stop signal)
X12, 10-pole Connection for the star axis track signals
X13, 10-pole Test connection for the Z axis track signals
X14, 10-pole not used
X15, 10-pole Test connection for the star axis track signals
X16, 10-pole Test connection for the DP axis track signals
Description Tools and equipment Values
Mount the star onto the motor
shaft of the star motor
Adjust with the power pack and
star zero point gauge
Check the magnetic neutral posi-
tion in SITEST
(max. deviation 95 digits)
Determine zero point correction
for the star.
Gauge for zero point correction /
SITEST
Enter result of zero point correc-
tion with SITEST
--> enter positions.
Switch position on star motor
(resolution of track signals 10 -
25)
none HF/X/D machines at switch posi-
tion 25
DP axis incremental encoder ad-
justment to the glass scale (seg-
ment)
Test probe 1.4 - 1.6 mm Distance 1.5 mm.
Adjustment mechanical position
of valve positioning drives
Distance gauge 0.2 mm or ad-
justment plunger
0.2 mm distance plunger to the
valve frame
Light barrier Z axis down Test probe 1.0 mm Distance 1.0 mm.
Clamping device on Z belt --- Tension jack must lie on the belt
teeth at the top and bottom.
9 C&P Placement Heads
9.5 Settings 9.5.2 Overview of Settings on the C&P6/12
178 Student Guide SIPLACE D-Series (FSE)
Belt tension of the Z axis Belt tension measurement de-
vice
Belt tension 280 +/- 5 Hz
Z axis top stop Gauge for Z axis end stopper -
star gauge [03019865-xx]
Correct position is necessary to
determine the zero point correc-
tion.
Air blast tubes on the star Check with your eyes Check the distance between in-
cremental encoder and air blast
tubes.
Adjustment of air blast supply Feeler gauge Air blast tubes should be approx.
0.7 mm over the frame of the cir-
cular arc guide
Adjustment of air blast placement Compressed air testing device 150 mbar on open 9x4 nozzle
Air blast setting on reject circuit Compressed air testing device250 mbar
Belt tension setting for drive belt
replacement
DP belt adjustment aid Achieved with spring tension of
tool
Description Tools and equipment Values
9 C&P Placement Heads
9.5.2 Overview of Settings on the C&P6/12 9.6 Room for Your Sketches and Notes
Student Guide SIPLACE D-Series (FSE) 179
9.6
9.6 Room for Your Sketches and Notes
Room for Your Sketches and Notes