00195440-05-SG_D-Series_FSE-EN - 第204页

11 Component Handling 11.3 Optional Extension on the CO T 11.3.4 Compressed Air Supply for Bulkcase Feeders 204 Student Guide SIPLACE D-Series (FSE) 11.3.4 1 1 . 3 . 4 C o m p r e s s e d A ir S u p p ly f o r B u lk c a…

100%1 / 290
11 Component Handling
11.3.2 Additional Tape Reel Container for Di-series 11.3 Optional Extension on the COT
Student Guide SIPLACE D-Series (FSE) 203
11.3.2
11.3.2 Additional Tape Reel Container for Di-series
Additional Tape Reel Container for Di-series
11.3.3
11.3.3 External Power Supply
External Power Supply
To keep the time for setup changeovers to a minimum, the component trolleys can be set up at an ex-
ternal setup location. The feeder module functions and settings can also be checked there as part of the
preparations for operation. An external power supply unit is available for this purpose. The component
trolley is supplied with the required operating voltage and compressed air via a supply cable.
Technical data
Scope of delivery
Voltage supply
Power supply cables (European and US standards)
Connection cables for the three machine types D1/D1i/D2/D2i, D3 and D4/D4i
Max. tape reel size Installation position of 3rd
holder
830 mm without splice detection 43.2 mm (17") Up
830 mm with splice detection 38.1 mm (15") Down
900 mm with splice detection 48.3 mm (19") Up
900 mm without splice detection 48.3 mm (19") Down
930 / 950 mm with or without splice detection 48.3 mm (19") Either
NOTICE
Cause of Hazard
For further details, refer to the installation guide for the "Adapter 3rd tape reel".
Additional Tape Reel Container (For only Di-Series)
Additional tape reel container is design to hold the 3
rd
reel
component from the 3 x 8mm Feeder. Each Di-series
COT is able to fix up to maximum 2 pcs of the additional
tape reel containers.
Legend
1. Each container is fixed to the COT via 4 screws
2. Height of container depends on the mounting screw
holes (High Height)
3. Height of container depends on the mounting screw
holes (Low Height)
4. Partition Plates.
Line voltage 230 V~ ±5 %
120 V~ ±5 %
Compressed air connection max. 1.0 MPa (10 bar)
Output pressure Adjustable via valve
11 Component Handling
11.3 Optional Extension on the COT 11.3.4 Compressed Air Supply for Bulkcase Feeders
204 Student Guide SIPLACE D-Series (FSE)
11.3.4
11.3.4 Compressed Air Supply for Bulkcase Feeders
Compressed Air Supply for Bulkcase Feeders
11.3.5
11.3.5 Fixtures for S-Feeders
Fixtures for S-Feeders
Compressed air supply for bulkcase feeders
Legend
1. Compressed air distributor
2. 2 x screw DIN 912, M8x20
3. Feeder table plate
4. Brackets
5. Compressed air connections for bulkcase feeders
Bulkcase feeders require compressed air. The optional
compressed air supply for bulkcase feeders is available
for this purpose.
Installation is easy. The compressed air distributor (1) is
fixed with two screws (2) to the changeover table (3). The
compressed air distributor is then connected to the com-
ponent trolley compressed air supply. At the back of the
compressed air distributor, there is a row of brackets (4).
These fix the bulkcase feeder modules to the changeover
table, ensuring optimum compressed air supply.
Feeder fixtures (HF shown as example)
Legend
1. Feeder fixtures
2. Changeover Table
The Feeder-Fixing is an additional mechanical safety
precaution. It prevents accidental movement of the feed-
er on the changeover table. It excludes a head crash risk
with a wrong positioned feeder. The feeder-fixation is
mounted on the front side of the changeover table. The
claws fix the feeder feet. A feeder clamp can be installed
for each of the component trolleys.
11 Component Handling
11.3.6 Additional Communication unit for splice detection 11.4 Pneumatic Tape Cutter
Student Guide SIPLACE D-Series (FSE) 205
11.3.6
11.3.6 Additional Communication unit for splice detection
Additional Communication unit for splice detection
11.3.7
11.3.7 Waffle Pack Changer (WPC)
Waffle Pack Changer (WPC)
To add a WPC4 in to a D1/D1i (D3: ab SR/MC 605) machine the following Steps are necessary:
Remove COT Location 1BE-Tisch Stellplatz 1 (D3: Location 2)
Remove the empty-tape duct assembly.
Remove the waste slide.
Remove the changeover table stopper.
Fit the fixed changeover table WPC4 and screw tight.
Assemble the empty tape canal
Insert the WPC, lower and align.
11.4
11.4 Pneumatic Tape Cutter
Pneumatic Tape Cutter
Additional Communication unit for splice detection
An additional communication unit for the option Tracea-
bility with splice detection is necessary. The splice sen-
sors on the communication unit inform the station
software when a new component lot (reel) is spliced on.
This sets the new fill level for this component automatical-
ly.
Legend
1. The additional communication unit is screwed into
place, together with the changeover table communi-
cation unit.
NOTICE
Cause of Hazard
. Take care not to confuse the WPC4 title with the Station numbering single WPCs
NOTICE
Cause of Hazard
With D1/D1i-Machine the S-feeders are on the right side of WPC4
With D3-Machine S-Feeders are left of the WPC4.
NOTICE
Cause of Hazard
The D4/D4i machine is used as an example to describe the pneumatic cutter.