00195440-05-SG_D-Series_FSE-EN - 第230页

12 Modular Conveyor 12.3 Conveyor Settings 12.3.2 Conveyor Control 230 Student Guide SIPLACE D-Series (FSE) Siemens/SMEMA TSP 301 In terface Description TSP 301 interface

100%1 / 290
12 Modular Conveyor
12.3.2 Conveyor Control 12.3 Conveyor Settings
Student Guide SIPLACE D-Series (FSE) 229
Conveyor Control TSP 301 with Siemens Interface
TSP 301 SMEMA --> Siemens
Legend
1. 10-pin plug for SMEMA interface
X3: upstream station
X4: successor station
2. Connection for Siemens interface
X1: upstream station
X2: successor station
NOTICE! Standard / Option
The SMEMA interface is a standard on all X machines
and the Siemens interface is optional.
The Siemens interface is a standard on all D/Di machines
and the SMEMA interface is optional. The SMEMA inter-
face requires an adapter when used with the D1/2/4/D1i/
D2i/D4i.
WARNING! Risk of irreparable damage to the
TSP board!
The 10 pin Locking clip plug of SMEMA connections must
be disconnected from the TSP 301!
Application: no modification.
Following modification are necessary for using the Sie-
mens interface:
JumperJ1 / J2: need to be moved (see following dia-
gram).
Disconnect the connector X3 and X4 on the TSP 301!
Connect the Siemens interface cable on the connec-
tor X1 and X2.
Jumper J1 and J2 (Siemens/SMEMA)
12 Modular Conveyor
12.3 Conveyor Settings 12.3.2 Conveyor Control
230 Student Guide SIPLACE D-Series (FSE)
Siemens/SMEMA TSP 301 Interface Description
TSP 301 interface
12 Modular Conveyor
12.3.2 Conveyor Control 12.4 Room for Your Sketches and Notes
Student Guide SIPLACE D-Series (FSE) 231
12.4
12.4 Room for Your Sketches and Notes
Room for Your Sketches and Notes