5 Energy and Compressed Air Supply 5.2.2 Overview of Power Supply 5.2 Power Supply Unit Student Guide SIPLACE D-Series (FSE) 81 With the open cov er, the state o f the following p rote ctive devi ces can be quite easily …

5 Energy and Compressed Air Supply
5.2 Power Supply Unit 5.2.2 Overview of Power Supply
80 Student Guide SIPLACE D-Series (FSE)
5.2.1.3
5.2.1.3 Overview of Power Supply D4/D4i
Overview of Power Supply D4/D4i
5.2.2
5.2.2 Overview of Power Supply
Overview of Power Supply
The main power supply unit is mounted on a compact slide-in module, and located on the left side of the
middle section. When viewed from the outside only the red main power switch is visible.
A lockable door prevents access to the power supply.

5 Energy and Compressed Air Supply
5.2.2 Overview of Power Supply 5.2 Power Supply Unit
Student Guide SIPLACE D-Series (FSE) 81
With the open cover, the state of the following protective devices can be quite easily monitored.
▪ Motor protection switch
▪ main contactor
▪ Safety relay
▪ Power circuit breaker
The following work must be performed to adjust the power supply to the country-specific requirements
(see also the conversion instructions for 3x 208 V to 3x 400 V and vice versa):
► Rewiring line supply cable/transformer
► Motor protecting switch
► Inrush current limiter connections
Main power supply - side view
Legend
1 Transformer 1 7 Power supply A1 (24 V/40 A)
2 Secondary terminal strip with fuses (output
voltage T1)
8 Line filter Z1 (input voltage)
8 Line filter Z1 (input voltage)
3 Connector strip X2-X10, X12, X13 9 Front view (see following diagram)
4 Terminal strip X1 10 Inrush current limiter (behind the cable
duct)
5 Power fail board A3
6 Power supply A2 (5 V/6.3 A) 11 Various rectifiers (V5 not in D1/D2/D1i/D2i)

5 Energy and Compressed Air Supply
5.2 Power Supply Unit 5.2.2 Overview of Power Supply
82 Student Guide SIPLACE D-Series (FSE)
Main power supply – front view (D4/D4i)
Legend
1. F1: 3x 230 V AC
SZ1: main contactor
MS1: Motor protection switch
S1: main switch
2. F2: 220 V AC for 5 V power supply
F4: 3x 140 VAC X/Y axes
SZ2,SZ3, SZ23: auxiliary contactors U,V,W for X/Y
servos
3. F5: 150 V DC star axis servo
F6: 40 V DC Z/DP axis servo
F7: 40 V DC changeover table
F8: 40 V DC PCB handling (conveyor)
F9: 8 V DC changeover table (only at D4/D4i)
F10: 48 V DC Vision illumination
F11: 24 V DC terminal strip distributor 2/4
F12: 24 V DC Microbox PC (MC)/control "ON" (K1)
F13: 24 V DC Box PC (SR)/axis unit 1/2
F14: 24 V DC conveyor control (TSP 301)/monitors
Z2: discharge inductor
4. K1: protective contactor combination
Relay1: control ON - button
SZ4: control ON - software
FU: fuse 6.3 AT 220 VAC to GND
FV: fuse 6.3 AT 220 VAC to GND
FW: fuse 6.3 AT 220 VAC to GND
FBU: fuse 6.3 AT 220 VAC to GND
X1: feed in - terminal strip
BU1: service socket