Fig. 4.2.3 Side view of power supply unit - transformers and rectifiers
4 Power Supply SIPLACE 80 S/F/G Service Manual
Edition 04/97
4 - 12
SIPLACE 80 S/F/G Service Manual 4 Power Supply
Edition 04/97
4 - 13
4.3 Control Unit
4.3.1 General
The control unit is located at the back of the SIPLACE machine in the machine base (see Fig. 4.1.1).
Open the metal door of the control unit.
In the top part of the control unit you will find power supply unit A26 with the associated voltage measure-
ment sockets (see Fig. 4.3.1).
4.3.2 Supply Voltages
Switch the main switch of the machine on.
Power supply unit A26 supplies these direct voltages: + 5 V, + 12 V, – 12 V, + 15 V, – 15 V and 24 V.
At the voltage measurement sockets measure the direct voltages listed here (see Fig. 4.3.1).
Fuse F1 is located in power supply unit A26 and protects against overload the 5 V voltage supply which is
routed to the gantries via the ribbon cable.
F1 is a 3.15 A fuse. Use the digital ohmmeter to check whether the fuse is okay.
NOTE
If automatic circuit-breaker F1 is defective this may result in faults in the limit switch loops (limit switch acti-
vated). When making detailed measurements or carrying out fault location in the terminal rails or circuits you