7 Components Table S IPLACE 80 S/F/G Servic e Manual Edition 04/97 7 - 14 – Break in th e motor cable (motor → plug X3 ak); moto r is de fective ( for repla cemen t see sect ion 7.6 " Empty Tape Cuttin g Unit a nd E…

100%1 / 484
SIPLACE 80 S/F/G Service Manual 7 Components Table
Edition 04/97
7 - 13
Fault in the compressed air feeder module or in the actuation of this module (output from the commu-
nications unit) or in the 5 bar compressed air branch for the components table compressed air supply:
See below, fault in the "components table pneumatic system / components table compressed air sup-
ply".
Machine data for tracks 1 or 120 are not correct: Check this with the SITEST program.
Faults in the placement head (faults: vacuum, nozzle, etc., see Service Manual, Section 9).
Error No. 388: "Checksum error in the table program"
The table program must be reinstalled.
Error No. 397: "Checksum error during communication with table"
Possible causes:
Transmission error: Select from within the machine errors menu "Continue".
Error No. 399: " Program loss of the table or trolley control"
Possible causes:
Back-up battery of the processor board (communications unit) must be replaced: See section 7.5
"Communications Unit". Note: With a cold restart the components table is automatically loaded; how-
ever this can also be effected by means of the single function "Load table" reached.
Error No. 400: RAM of the trolley control system is defective
Possible cause:
Hardware fault: replace the communications unit (see section 7.5 "Communications Unit").
Error No. 407: "Communication with table interrupted"
Possible causes:
Fuse F1 on the input side of the components table-transformer is defective: determine the cause and
replace the fuse (see section 7.3 "Components Table Power Supply").
Interface connector or voltage supply plug has been pulled or there is a bad contact or cable break-
age: check plug connection, if necessary, replace cable.
7.2.1.1 Faults in the Empty Tape Cutting Device
Tape back-up in the empty tape channel / tapes are not being cut
Possible causes:
The motor of the tape cutting unit is not being activated:
The +30 VDC fuse of the communications unit (connections panel) is defective.
Bad plug connection at the tape cutting unit or at the communications unit.
Motor current being switched out by the overload protection (PTC thermistor, communications
unit):
Cutter wheel is stiff-running; pretensioning of the cutter wheel is too strong; continuous or cut
toothed belt is overtensioned; guide rail and carriage for the cutting movement have not been
maintained (see User’s Manual section 9).
7 Components Table SIPLACE 80 S/F/G Service Manual
Edition 04/97
7 - 14
Break in the
motor cable
(motor
plug X3ak); motor is defective (for replacement see section
7.6 "Empty Tape Cutting Unit and Empty Tape Channel").
Interruption on the "Flap opener controller" board (+30 VDC power circuit / signal for tape cutter:
processor board, plug X5
board "Flap opener controller" (IC)
processor board, plugs X4: for
fault location see section 7.6 "Empty Tape Cutting Unit and Empty Tape Channel"; correction by
replacing the "Flap opener controller" board (see section 7.4 "Flap Opener (Magazine Openers)").
The carriage has driven onto the righthand stop: righthand limit switch is defective, or there is a
break in the limit switch cable (leading to the motor current being switched out by the PTC ther-
mistor).
The cutter wheel carriage does not return to the parking position (after reaching the righthand limit
switch it remains where it is): break in the "Home position" cable or in the lefthand limit switch.
The carriage has driven onto the lefthand stop: lefthand limit switch is defective, or there is a
break in the limit switch cable (leading to the motor current being switched out by the PTC ther-
mistor).
The cutter wheel is worn out (maintenance - see User’s Manual Section 9). Correction: Replace cutter
blade and cutter wheel; then, pretension the cutter wheel (see section 7.6 "Empty Tape Cutting Unit
and Empty Tape Channel").
The pretensioning of the cutter wheel is inadequate which means the tape is not being cut.
The pressure rod is not swinging in far enough: the tension springs are fatigued or have detached.
The setting of the swivel movement is incorrect: see the ssection 7.6 "Empty Tape Cutting Unit and
Empty Tape Channel".
At cycling on, the tapes will not move; or the tape pressure rod does not swing away
Possible causes:
The 5.6 bar compressed air branch (= operating pressure) from the compressed air unit to the tape
cutting unit is leaky or the compressed air hose is pinched.
The compressed air cylinder is defective: replace.
The solenoid valve at the tape cutting unit is not being actuated; there is a break the cable (plugs X3ak
solenoid valve); the solenoid valve is defective; there is a fault in the communications unit.
The swivelling movement of the pressure rod is being restricted by a mechanical obstacle or it has
been adjusted incorrectly: (see section 7.6.12.4 "Adjusting the Swivel Movement, Replacing the Ten-
sion Springs").
Individual tapes are not being cut or are backing up in the empty tape channel
Possible causes:
The fins in the empty tape channel are bent or are no longer touching the outer guide plate an: replace
and adjust the "inner guide plate" or the complete empty tape channel.
The tapes of the outer tracks (1 and/or 120) are not being cut:
The switching point of the corresponding limit switch has been set incorrectly (the cutting stroke
should be 656 mm; see section 7.6 "Empty Tape Cutting Unit and Empty Tape Channel").
Only the tapes of the first tracks (from 1 upwards) are not being cut correctly:
The pressure rod is swinging in too slowly or bounces: adjust the exhaust air restrictor at the sole-
noid valve (see section 7.6.15 "Concluding Work").
The empty tape channel was not aligned symmetrically with the pressure rod when it was refitted.
SIPLACE 80 S/F/G Service Manual 7 Components Table
Edition 04/97
7 - 15
7.2.1.2 Fault in the Vibrator Activation
An individual vibratory feeder (vibrator) in the activated feeder sector/location (1; 3) is failing to
convey components
Possible causes:
The vibratory feeder will not activate (Check: "Refill track"
select linear feeder): electrical interrup-
tion in the vibratory feeder or in the power supply cable; poor contact in the plug connection at the
connections panel.
Interruption in the 24 VAC supply voltage at the corresponding connection socket (LED on the con-
nections panel illuminates) or the vibrator controller of the communications unit: check the plug con-
nections; if necessary, replace the communications unit.
The period of time for vibrator activation has been input incorrectly (see User’s Manual for the UNIX
line computer, Section 5, under "Coordinates Correction").
The vibration intensity has not been set correctly at the potentiometer rotary button (on the connec-
tions panel of the communications unit): see below, section 7.2.1.2 "Fault in the Vibrator Activation".
The basic calibration of the vibratory feeder needs readjusting.
There is no vibrator (= vibratory feeder) defined in this track: see User’s Manual for the UNIX line com-
puter, under "Feeder Part Editor".
The vibratory feeders of an entire feeder sector or location (1; 3) are not being activated
Possible causes:
No vibratory feeders are defined at this location (see User’s Manual for the UNIX, under "Feeder Part
Editor").
There is no voltage at the components table: the fuse on the input side of the transformer components
table is defective (leads to error message "Communication with table faulty"): see section 7.3 "Compo-
nents Table Power Supply".
Defect in the vibrator control circuit; interruption within the communications unit: replace communica-
tions unit.
7.2.1.3 Fault in the Flap Opener (Magazine Opener)
An individual flap opener will not activate, the plunger does not extend / retract
Possible causes:
No linear vibratory feeder or 24/32 mm tape feeder module (blister tapes) has been defined for this
installation point or track (see User’s Manual for the UNIX computer, "Feeder Part Editor").
The "Components supply - flap openers" ribbon cable is defective; there is a bad plug connection:
replace the cable.
The associated solenoid valve is not switching: electrical interruption on the "Flap opener controller"
board or the solenoid valve on this board is defective: replace controller board.