80S-15贴片机 - 第216页

7 Components Table S IPLACE 80 S/F/G Servic e Manual Edition 04/97 7 - 34 7.6.2 Locating the Electrical Fault NOTE Error mess age No. 43 can point to a fault in the tape cutti ng unit or in the empty tape channe l. Start…

100%1 / 484
SIPLACE 80 S/F/G Service Manual 7 Components Table
Edition 04/97
7 - 33
7.6 Empty Tape Cutting Unit and Empty Tape Channel
7.6.1 Tools and Spare Parts Required
Tools
Screwdrivers for socket-head cap screws, set
Standard screwdrivers, set
Side-cutting pliers; if necessary, hot air gun
2 open-ended spanners, size SW 17; 1 open-ended spanner, sizes SW8 and SW10
Pincers for shaft circlips 10x1 and 8x1 (for removal of the compressed air cylinder)
Auxiliary Measuring and Test Equipment
Slide gauge
Measuring tape (for cutting stroke)
Measuring probe with magnetic holder (contained in the SIPLACE service carrying case)
Multimeter, range of measurement 30 VDC / ohmmeter
Belt tension measuring device, from Item No. 00326015-01 (including documentation)
Plastic sheet for cutting test (approx. 0.2 mm thick)
Spare Parts
Empty tape cutting unit:
Blade, from Item No. 00316577-02
Cutter wheel, from Item No. 00308663-02
Cut toothed belt Synchroflex 6AT3/918, from Item No. 00308676-01
Cut toothed belt Synchroflex 10AT3/1500, from Item No. 00316602-01
Micro switches, series 1006, from Item No. 00308607-01
Motor unit, from Item No. 00314227-06
Cable: Motor / limit switch - tape cutter Y0637, from Item No. 00313401-02
3/2-way solenoid valve, from Item No. 00310746-01
Tension spring for tape cutter, from Item No. 00316304-01
Compressed air cylinder, double-acting, from Item No. 00310659-01
Silencer G-118, from Item No. 00310744-01
If applicable, compressed air hose (for 5.6 bar minimum)
Restrictor valve GRLZ-M5-PK-3-B, from Item No. 00312103-01
Exhaust air restrictor GRE-1/8, from Item No. 00312101-01
Cable lacing
Tape cutting unit SIPLACE 80, from Item No. 00315060-02
Fine-wire fuse 5x20/T 4.0 A
Empty tape channel:
Empty tape channel, complete from Item No. 00308313-04
7 Components Table SIPLACE 80 S/F/G Service Manual
Edition 04/97
7 - 34
7.6.2 Locating the Electrical Fault
NOTE
Error message No. 43 can point to a fault in the tape cutting unit or in the empty tape channel. Start fault loca-
tion by referring to the section 7.2 "Fault Characteristics".
- In addition, in the section 7.1.4 "Empty Tape Cutting Device" you will find information on the electrical and
pneumatic systems as well as the functional sequence for evaluating the fault situation.
- Use the circuit diagrams from the current circuit diagram folder. Details at to which diagram is needed
in each case will be found in the following text.
- In the course of fault location you will require the SITEST program for performing an individual cutting
stroke or starting continuous operation.
DANGER
OOO
When the SITEST program is being used, particularly with the components changeover table removed (but
connected), there is increased risk of accidents at the tape cutting unit involving the cutter wheel and cutter
strip. When the test program is loaded do not reach into the area of the tape cutting unit, not even for fault cor-
rection or to connect up a multimeter, etc. Cordon off the area of the tape cutting unit correspondingly.
With all work, please read and observe in addition the DANGER note in the section 7.2 "Fault Characteristics"
7.6.2.1 Checking the + 30 V Electric Circuit: Fuse, Plug Connections,
Motor Activation, Solenoid Valve
Select from within the track error menu "Abort placement" in order to return in the course of the following
reference run all of the components picked up at the placement heads.
Check whether fuse F1 of the connections panel of the communications unit has interrupted the + 30 VDC
electric circuit (see Fig. 7.5.1 and circuit diagram 1710470-Y0069-..-L.., Sh. 1).
Fuse F1 is defective:
Switch off the machine at the main switch.
First correct the cause - such as, for example, a short circuit in the limit switch, in the cable Y637-W1/
W2, etc. (for fault location, see below) or in the tape feeder module - and then replace the fuse F1.
Switch the machine back on and carry out a trial placement run with component pick-up from the tape
feeder modules of the previously faulty location.
If no error message now occurs (the tapes are being cut), start the placement sequence.
Fuse F1 is not defective:
Load the SITEST program and start the cutting stroke by making the following selection:
"BE table"
"Single function"
"Tape cutter". Check whether the cutting stroke is being carried out,
the pressure rod is swinging into position, the cutter wheel carriage returning to its parking position on
the left, the motor current being switched off and the pressure rod swinging away.
The motor is being switched off after brief activation: there is stiffness in the performance of the cutting
stroke
the + 30 VDC electric circuit has been interrupted by the PTC thermistor:
Check whether the longitudinal guide of the slide has been maintained (see User's Manual,
SIPLACE 80 S/F/G Service Manual 7 Components Table
Edition 04/97
7 - 35
Sec.9).
Check the pretensioning of the cutter wheel (see the section which follows).
If necessary, correct the toothed belt tension of the cut and endless toothed belt
(see Section below).
No motor activation, but the pressure rod swings into position (= solenoid valve switches):
The motor is defective or there is an interruption between the motor and the plug X3ak at the tape
cutting unit
No motor activation and the pressure rod does not swing into position (= solenoid valve is not switch-
ing):
Check the plug connections, the limit switches and the cable Y637/Y638, as described below.
Motor activation, but the pressure rod does not swing in:
Check the wiring of the valve and compressed air circuit; if necessary, replace the solenoid valve.
After the motor has switched out: pressure rod does not swing out: the solenoid valve is defective
(does not return to initial position).
7.6.2.2 Checking the Limit Switch and Cable Y637, Y638
"Abort placement" has already been selected (see above).
GEFAHR
QQQ
Switch off the machine at the main switch and disconnect it from the power supply.
Removing the components changeover table:
Undo the plug connections of the components changeover table at the machine base on the right of
the components changeover table (mains plug and interface connector X37, and, if applicable, the
pneumatics connection).
Open the protective covers and lift the cover at the components loading point upwards and out. Slide
the placement head by hand over the board conveyor. Please read the CAUTION note in section 7.2
"Fault Characteristics".
Cut off the empty tapes - if they have not already been cut - at the front end of the module (= outside).
Release the tape retainer and use a lift truck to lift and move the components changeover table (including
any feeder modules being used) carefully out of the machine as described in the User’s Manual.
The empty tape cutting unit remains installed in the machine for the following work.
CAUTION:
OO
Do not reach into the area of the cutter strip and cutter wheel: danger of physical injury!