00198171-02_Technical_Training_FSE_TX-Series_EN - 第144页
9 Station Software Overviews 9.7 Maintenance GUI 144 Technical Training FSE SIPLACE TX-Series 01/2018 Content Preventive Maintenance page Status overview of Vacuum-, height- and scan values with the production nozzles sh…

9 Station Software Overviews
9.7 Maintenance GUI
Technical Training FSE SIPLACE TX-Series 01/2018 143
General function:
1. Select Head, Location, Gantry
2. Comments field for reports
3. Show the result of each function
4. Show the details for the selected function
in the result window
5. Report* with results and details of the func-
tion which was carried out
* The Reports will be save on the station computer and transfer via the SW Line diagnostic to the
SIPLACE Pro computer.
Storage Location
Station: C:\Sirio\Work\MaintenanceReports
SIPLACE Pro: C:\MaintenanceReports
User Level "Operator"
1. Maintenance machine functions
2. Shows the result of each function
3. If an error occurs, the detail button shows
more information
4. The report shows all results with details
CAUTION
The machine required a recipe to carry out the preventive maintenance steps.

9 Station Software Overviews
9.7 Maintenance GUI
144 Technical Training FSE SIPLACE TX-Series 01/2018
Content Preventive Maintenance page
Status overview of Vacuum-, height- and scan values with the production nozzles shows the dis-
abled DP´s and EXIT Button back to Maintenance GUI.
Return nozzle in the nozzle changer., Gantry moves in the Setup position and remove all tables if
possible (SX). Machine is ON.
Two cuts for selected tape cutter to check the blades and cycle time.
Check and show the Fan monitoring. (SIPLACE TX).
Check the filter disk via the component sensor on C&P20 Heads.
Pick up production nozzles to verify this nozzles with the next steps.
Check the seat of the nozzles on the DP´s. (all CPx Heads).

9 Station Software Overviews
9.7 Maintenance GUI
Technical Training FSE SIPLACE TX-Series 01/2018 145
Check the anti glare shield by turning the DP and the component sensor. (C&P20 A/M Heads only).
Report for the maintenance staff. Shows the results of all tests which was carried out and the com-
ments.
Endurance run with all main axes and head axes and a complete reference run 3 cycles.
Return production nozzle (pick up calibration nozzle if available), Gantry in Setup position and re-
move all table if possible (SX). Machine shut down.
Return all nozzle in the nozzle changer to remove the hole magazine and clean the nozzle.
9.7.3 Predictive Maintenance
User Level "Service Customer"
1. Show the maintenance status of the sub-
systems
2. Head test bench, complete head test and
reporting