00198171-02_Technical_Training_FSE_TX-Series_EN - 第76页

6 Conveyor System 6.5 Parts Exchange / Settings / Calibration 76 Technical Training FSE SIPLACE TX-Series 01/2018 6.5.2.4 Board reference corner 1. Log on as Machine service (1-3). 2. Click Calibration (1). Click Automat…

100%1 / 168
6 Conveyor System
6.5 Parts Exchange / Settings / Calibration
Technical Training FSE SIPLACE TX-Series 01/2018 75
5b. Alternatively enter board width value (Key
in the current PCB width).
6. Click Save machine data for conveyor.
6 Conveyor System
6.5 Parts Exchange / Settings / Calibration
76 Technical Training FSE SIPLACE TX-Series 01/2018
6.5.2.4 Board reference corner
1. Log on as Machine service (1-3). 2. Click Calibration (1).
Click Automatic calibration (2).
3. Select Board reference corner (1).
Click Next (2).
4. Select Conveyor (1).
Click Start (2).
5. Click Accept to save data and close.
6 Conveyor System
6.5 Parts Exchange / Settings / Calibration
Technical Training FSE SIPLACE TX-Series 01/2018 77
6.5.2.5 Teaching the sensor
1. Log on as Machine service (1-3). 2. Click on Check sensors icon (1).
Select Specific functions (2).
3. Click Conveyor Input/output. 4. Click on Sensor.
5. Click on red box Teach board sensor. 6. Click Select enable.
Click OK.