F5 SERVICE MAUNAL - 第230页

7 Components Table SIPLACE 80 S-20/F4 Service Manual 7.5 Communications Unit Edition 03/97 7 - 28

100%1 / 483
SIPLACE 80 S-20/F4 Service Manual 7 Components Table
Edition 03/97 7.5 Communications Unit
7 - 27
menu "Component feeding" "Location" "Vibrate linear feeder" Return. The output for the vibra-
tory feeder will remain set until you cancel the function "Vibrate linear feeder" (toggle function).
With SITEST program version 1.64 loaded, select: "Functions" "Component table" "Single func-
tions" "Track" "Actuate lin. feeder" enter the vibration period Return.
While the vibration intensity is being activated, turn the corresponding potentiometer rotary button (see
Fig. 7.5.1) until the component is conveyed forward briskly but does not "jump" in the track.
7.5.2.7 Replacing the Communications Unit
Complete the SITEST program.
DANGER QQQ
Switch off the machine at the main switch and disconnect it from the main power supply.
Open the protective cover and pull the protective cover at the components feed point upwards and away.
If necessary, cut the tapes at the front end of the module and pull the remaining tape with components
backwards and out. Roll the tape back onto the reels. The tape reels remain in place in the compartments
as their allocation to the track must be retained.
NOTE:
If you have already unintentionally removed tape reels / feeder modules, restore their original arrange-
ment as described in the User Manual, Section 9 , under "Components tables".
Pull out all plugs of the feeder modules which are plugged into the connections panel of the communica-
tions unit. The feeder modules will remain in place unchanged.
Undo the mounting of the front panel of the communications unit (6 recessed head screws M3) and pull the
unit front panel including boards forwards and out a little:
Undo the plug connections of the cables coming in from the back and
the screws fastening the housing to the frame (4 socket-head cap screws M4, see Fig. 7.5.1).
Remove the communications unit out of the frame from the front.
Install the new communications unit in the reverse sequence of operations. Before refitting the front panel
make sure all plug connections are firmly seated and the back-up battery (see Fig. 7.5.1) is in place.
Plug all feeder modules into their associated sockets. Insert all tapes into the modules.
Reconnect the plug connections of the components changeover table in the machine base, connect the
machine to the power supply, switch the machine on.
Check the activation of the LED for the 24 VAC voltage on the connections panel.
Check the functioning of the new communications unit using the SITEST program or by component pick-
up from this location. After this, start the placement sequence.
7 Components Table SIPLACE 80 S-20/F4 Service Manual
7.5 Communications Unit Edition 03/97
7 - 28
SIPLACE 80 S-20/F4 Service Manual 7 Components Table
Edition 03/97 7.6 Empty Tape Cutting Unit and Empty Tape Channel
7 - 29
7.6 Empty Tape Cutting Unit and Empty Tape Channel
7.6.1 Tools and Spare Parts Required
Tools
Screwdriver for socket-head cap screws, sizes 1.5 to 4
Standard screwdriver, sizes 3, 4
Side-cutting pliers; if necessary, hot air gun
2 open-ended spanners, width across flats 17; 1 open-ended spanner, widths across flats 8 or 10
Pincers for shaft circlips 10x1 and 8x1 (for removal of the compressed air cylinder)
Auxiliary Measuring and Test Equipment
Slide gauge
Measuring tape (for cutting stroke)
Measuring probe with magnetic holder (contained in the SIPLACE service carrying case)
Multimeter, range of measurement 30 VDC / ohmmeter
Belt tension measuring device, from item no. 00326015-01 (including documentation)
Plastic sheet for cutting test (approx. 0.2 mm thick)
Spare Parts
Empty tape cutting unit:
Blade, from item no. 00316577-02
Cutter wheel, from item no. 00308663-02
Cut toothed belt 6AT3/918 (cutter wheel), from item no. 00308676-01
Cut toothed belt 10AT3/1500 (carriage), from item no. 00316602-01
Limit switches (micro switches) left and right (qty. 2), from item no. 00308607-01
Motor unit, from item no. 00314227-06
Cables for switches, left-hand and right-hand, motor, Y637-W2, from item no. 00313401-02
3/2-way solenoid valve, from item no. 00310746-01
Tension spring 7.5 x 106 x 1.25 (qty. 2), from item no. 00316304-01
Compressed air cylinder, double-acting, from item no. 00310659-01
for cylinder, from item no. 00310744-01
If applicable, compressed air hose (for 5.6 bar minimum)
Restrictor valve, from item no. 0031210301
Exhaust air restrictor, from item no. 00312101-01 (including silencer)
Cable lacing
Empty tape cutting unit, complete, from item no. 00315060-02
Fine-wire fuse 5x20/T 4.0 A
Empty tape channel:
Empty tape channel, long, complete from item no. 00308313-04