SU_UM_TME20822_EN.pdf - 第20页
20 Smart-UPS S MTL 22 00/3000 RMI2UC/RMI2UCNC Op e ra t i on EN TME2 08 22 – 08/2 023 Advanced menus The A dvanced menus provide additional options for the UPS and are available o nl y if the di s play i nterface is c on…

19
Operation
Smart-UPS SMTL 2200/3000 RMI2UC/RMI2UCNC
EN TME20822 – 08/2023
Standard menus
The Standard menus are the most commonly used menus. The following is a list of
some items displayed in this menu mode. Visit apc.com for additional details.
Menu General Functions
Status View UPS information:
• Operating Mode
• Efficiency
• Load Power
• Load VA
• Battery Charge state
• Estimated Runtime
•Battery Temp
• Input
• Output
• SmartConnect
• Probe 1, Probe 2, when NMC
and sensor probes are
installed
Configuration Configures UPS settings:
• Language
• Green Mode
• Local Power Quality: Good,
Fair, Poor
• Menu Type: Standard or
Advanced
• Audible Alarm
• Display (Auto Dim, Auto Off,
Always On)
• Reset to Factory Default
• SmartConnect Control
•Install FW?
Note: Enabled only if a
firmware update is available.
Test & Diags Performs UPS tests and
diagnostic functions:
• UPS Self Test
• UPS Alarms Test
About View UPS information:
• UPS Model
• UPS Part No.
• UPS Serial No.
• UPS Manufacture Date
•Battery Part No.
• Battery Install Date
• Replace Battery by
• Running UPS FW
• Available UPS FW
Note: Enabled only if a UPS
firmware update is available.
•UPS MAC
• UPS IP Address
• UPS Product Key
• SmartSlot Card (if installed)

20
Smart-UPS SMTL 2200/3000 RMI2UC/RMI2UCNC
Operation
EN TME20822 – 08/2023
Advanced menus
The Advanced menus provide additional options for the UPS and are available only if
the display interface is configured to use the Advanced menus.
Menu General Functions
Status View detailed UPS information:
• Operating Mode
• Efficiency
• Load Power
• Load VA
• Load Amps
• Load Energy
• Battery Charge State
• Estimated Runtime
• Battery Voltage
•Battery Temp
• Input
• Output
• Outlet Groups
• SmartConnect
• Probe 1, Probe 2, when NMC
and sensor probes are
installed
Control Controls the Main and Controlled Outlet Group to turn on, turn off,
shutdown, or reboot:
• UPS Control
• Outlet Group Control
Configuration Configure advanced UPS
settings:
• Language
• Output Voltage
Note: Setting can be
configured only when UPS
output is turned off.
• Green Mode
• Local Power Quality
• Menu Type
• Audible Alarm
• Display
• Sensitivity
• Low Transfer
• High Transfer
• Low Battery Setting
• Auto Self Test
• Reset Energy Meter
• Enter Setup Wizard
• Reset to Factory Defaults
• Site Wiring Fault
• Config Main Group Outlets
• Config Group Outlets (if
Controlled Outlet is available)
• ModBus Settings
• SmartConnect Control
• UPS IP Address Setting
• NMC IP Address Settings (if
NMC is available)
• FW Update Interfaces
• Install FW? (only available if a
firmware update is available)
Test & Diag Perform UPS tests and
diagnostics functions:
• UPS Self Test
•UPS Alarms Test
Logs View the error log for information about UPS errors that have
occurred.

21
Operation
Smart-UPS SMTL 2200/3000 RMI2UC/RMI2UCNC
EN TME20822 – 08/2023
About View UPS information:
• UPS Model
• UPS Part No.
• UPS Serial No.
• UPS Manufacture Date
• Battery Part No.
• Battery Install Date
• Replace Battery by
• Running UPS FW
• Available UPS FW
Note: Enabled only if a UPS
firmware update is available.
• UPS MAC
• UPS IP Address
• UPS Product Key
• SmartSlot Card (if installed)
Menu General Functions