00194923-01_OIS_DB.pdf - 第23页

OIS Datenbank Version 4.1 Schnittstellenbeschreibung OIS Database Version 4.1 Interface Description 23 von 47 3475 Difference in vacuum too great between placement and pick-u p 3513 Vision system: Flipped compone nt dete…

100%1 / 47
Schnittstellenbeschreibung OIS Datenbank Version 4.1
Interface Description OIS Database Version 4.1
22 von 47
2085 No. of pins: no result
2086 No. of pins: no result (Corner)
2087 No. of pins: no result (Lead)
2088 Colinearity: no result
2089 Colinearity: no result (Corner)
2090 Colinearity: no result (Lead)
2091 Spacing: no result
2092 Spacing: no result (Corner)
2093 Spacing: no result (Lead)
2094 Position: component outside feed tolerance
2095 Position: component outside feed tolerance (Size)
2096 Position: component outside feed tolerance (Row)
2097 Position: component outside feed tolerance (Corner)
2098 Position: component outside feed tolerance (Lead)
2099 Position: component outside feed tolerance (Grid)
2100 Position: component outside feed tolerance (Ball)
2101 Dimension: component outside feed tolerance
2102 Dimension: component outside feed tolerance (Size)
2103 Dimension: component outside feed tolerance (Row)
2104 Dimension: component outside feed tolerance (Corner)
2105 Dimension: component outside feed tolerance (Lead)
2106 Dimension: component outside feed tolerance (Grid)
2107 Dimension: component outside feed tolerance (Ball)
2108 No. of pins: component outside feed tolerance. Sequential error
2109 No. of pins: component outside feed tolerance (Corner)
2110 No. of pins: component outside feed tolerance (Lead)
2111 Colinearity: component outside feed tolerance. Sequential error
2112 Colinearity: component outside feed tolerance (Corner)
2113 Colinearity: component outside feed tolerance (Lead)
2114 Spacing: component outside feed tolerance. Sequential error
2115 Spacing: component outside feed tolerance (Corner)
2116 Pitch: Component outside feeding tolerance (Lead)
2277 The difference between open and closed vacuum values is too small
2424 Coplanarity: Bad component, to be returned
2451 Coplanarity: Component cannot be measured (excessive offset in lead direction)
2452 RV-head: Segment not airtight after placement
2453 IC-head: Segment not airtight after placement
2454 Nozzle contaminated or worn out
2455 Vacuum value of segment too low with valve closed
2516 Warning: Nozzle is slightly soiled
OIS Datenbank Version 4.1 Schnittstellenbeschreibung
OIS Database Version 4.1 Interface Description
23 von 47
3475 Difference in vacuum too great between placement and pick-up
3513 Vision system: Flipped component detected
3553 Component not on nozzle prior to dipping
3570 Component on the nozzle before pickup pr nozzle dirty
3573 Nozzle dirty or obstruction during pickup
13005 Coplanarity module: Component faulty
15265 Cover foil on tape feeder damaged
15266 Cover foil not removed from tape feeder
17410 Warning RV head: Segment not airtight after placement
18109 Nozzle could not be identified by component sensor
18132 Warning: No component available for placement
18133 Warning: Nozzle is soiled
18134 Warning: Measured component height too large
18135 Warning: Measured component height too small
18136 Nozzle worn
18137 Track empty error detected by component sensor
18139 Nozzle soiled before pick-up
18509 Vacuum not achieved (no component on the nozzle)
18510 Vacuum not achieved (component not located securely on the nozzle)
18517 The difference between open and closed vacuum values is too small
18554 Component not at nozzle after pick-up
18555 Component not on nozzle prior to placement
18557 Nozzle not empty prior to pick-up
18558 Nozzle not empty after placement
18560 Error in feeder on pick-up
18565 Component not at nozzle after pick-up
18566 Component not at nozzle before placement
18567 Component not on nozzle during dipping
18570 Component not on nozzle prior to dipping
18916 Component cannot be picked up with the selected head type
18921 (Bauelement wird abgeholt, bevor die Abholposition erreicht wird)
19112 Component not seated on nozzle correctly on pickup
21017 Component picked up at wrong angle
21424 Component description for measurement with SIPLACE Vision incomplete
21802 Component outside feed tolerance
21803 Component rotation angle outside tolerance
21804 Measured offset in X and Y outside presentation tolerance
21805 Measured offset in X outside presentation tolerance
21806 Measured offset in Y outside presentation tolerance
21811 Position cannot be determined
Schnittstellenbeschreibung OIS Datenbank Version 4.1
Interface Description OIS Database Version 4.1
24 von 47
21812 Component inspection failed
21813 Size check failed
21815 Flipped component detected
21816 Quality is too low for optical centering
21817 No component in front of the camera or component not bright enough
21821 Measured size outside tolerance
21822 Measured size in X outside tolerance
21823 Measured size in Y outside tolerance
21826 Position (approcimate) cannot be determined
21827 Angle (approcimate) cannot be determined
21828 Position (fine) cannot be determined
21831 Not all features of the component were detected
21832 Not all ball features of the component were detected
21833 Features outside positional tolerance
21834 Ball features outside positional tolerance
21841 Nozzle is soiled
21842 Nozzle duct blocked
21843 Nozzle wom
22001 X-Feeder: Component was not transported into specified position in the defined time.
21880 Measurement with 3D sensor failed
21881 Measurement with 3D sensor: Not all connections were found
21882 Measurement with 3D sensor: At least one connection is damaged
21883 Measurement with 3D sensor: Coplanarity outside tolerance
21884 Measurement with 3D sensor: Distance between component and sensor too small
21885 Measurement with 3D sensor: Distance between component and sensor too large
21886 Measurement with 3D sensor: Component tilted too much
22002 X-Feeder: Component was not transported into specified position in the defined time.
22004 X-Feeder: Foil tom
22005 X-Feeder: Foil removal incorrect
22006 X-Feeder: Foil removal device blocked
22015 X-Feeder: Feeder not mounted or communication to feeder interrupted.
22017 X-Feeder: Tape drive of the feeder is not referenced
22018 X-Feeder: Low foil tension