00195779-0102_UM_D4_SR605_EN - 第244页
6 Station extensions User manual SIPLACE D4 6.10 01005 package From software version SR.605.xx 07/2008 EN Edition 244 6.10 01005 p ackage Item no. 001 19920-xx 01005 package for D4/D2 / D1 The SIPLACE D4 machine is alrea…

User manual SIPLACE D4 6 Station extensions
From software version SR.605.xx 07/2008 EN Edition 6.9 C&P high-resolution CO camera, type 29, 27 x 27, digital
243
6.9 C&P high-resolution CO camera, type 29, 27 x 27, digital
Item no. 00119779-xx High-resolution camera, C&P12, digital
6.9.1 Structure
6
Fig. 6.9 - 1 C&P component camera, type 29, 27 x 27, digital
(1) Component camera lens and illumination
(2) Camera amplifier
(3) Illumination control
6.9.2 Technical data
6
Component dimensions 0.3 x 0.3 mm² to 18.7 x 18.7 mm²
Range of components 0201 to 27 x 27 mm²
PLCC, SO, QFP, TSDP, SOT, MELF, CHIP, IC BGA
Min. lead pitch 0.3 mm
Min. lead width 0.15 mm
Min. ball pitch 0.25 mm
Min. ball diameter 0.14 mm
Field of vision 32 x 32 mm²
Method of illumination Front-illumination (5 levels, programable as required)
6 Station extensions User manual SIPLACE D4
6.10 01005 package From software version SR.605.xx 07/2008 EN Edition
244
6.10 01005 package
Item no. 00119920-xx 01005 package for D4/D2/D1
The SIPLACE D4 machine is already prepared to place 01005 components. In order to process
01005-BE one simply needs upgrading of the 12-segment Collect&Place head. The retrofitting
package contains the following parts:
– CO camera, C&P, type 38, 16 x 16, digital Item no. 03051870-xx, 1x
– A type 12 sleeve complete, 270°-sub-division Item no. 03054107-xx, 3x
– Nozzle, type 905 ESD, 1 x 0.15 Item no. 03057320-xx, 12x
– Assembly instructions 01005 package for D4/D2/D1
German and EnglishItem no. 00195398-xx, 1 piece
6.11 0201 package
Item no. 00119720-xx 0201 package for C&P12, X/D series
We can supply the 0201 package for processing 0201 components with the 12-segment Col-
lect&Place head.
This contains:
– C&P component camera (type 29), 27 x 27, digital, item no. 00119779
– Component sensor for the 12-segment C&P head, item no. 00118021
– 12 nozzles, type 706/906 Vectra ceramic, item no. 00345031

User manual SIPLACE D4 6 Station extensions
From software version SR.605.xx 07/2008 EN Edition 6.12 Vacuum pump
245
6.12 Vacuum pump
Item no. 00119017-xx Vacuum pump
Item no. 00119406-xx Connection kit for vacuum pump
Every Collect&Place head has a separate vacuum generator that supplies the holding and place-
ment circuit with the vacuum that it needs. The vacuum generator works on the Venturi principle.
The machine's compressed air consumption is approximately 950 Nl/min, which means that the
compressed air supply must be dimensioned accordingly. If the owner does not have sufficient ca-
pacity locally, the associated investment costs would be high, so we supply a vacuum pump that
will provide the necessary vacuum.
Other advantages of using the vacuum pump are:
– It roughly halves the machine's compressed air consumption.
– It reduces the input pressure.
– The machine can be easily integrated into existing lines.
– The ongoing operating costs reduce according to the energy costs.
The vacuum pump is maintenance-free and 100% oil-free. It has sufficient capacity to supply the
holding circuits of the Collect&Place heads.
Compressed air consumption of the machine
a
a) Under normal atmospheric conditions at 20°C and 1013 hPa
Without vacuum pump 950 Nl/min
With vacuum pump 400 Nl/min