User manual SIPLACE D4 2 Operational safety From software version SR.605.xx 07/2008 EN Edition 2.8 Dis abling the compressed air suppl y and discharging the pr essure 75 2.7.2 Residual volt ag es and discharge times af t…

100%1 / 266
2 Operational safety User manual SIPLACE D4
2.7 Residual voltages and discharge times in the machine From software version SR.605.xx 07/2008 EN Edition
74
Fig. 2.7 - 2 Measuring points on the power supply unit
2
2.7.1 Operating voltages, residual voltages and discharge times after pressing
the emergency stop button
2
Pin X14 and terminal P150 (X1)
measured to X15 (GND)
Voltage in
normal mode
Residual voltage
after EMERG.
STOP
Discharge
times
X14 + 200 VDC < 60 VDC 4 s
P150 (X1) + 150 VDC < 60 VDC 1 s
User manual SIPLACE D4 2 Operational safety
From software version SR.605.xx 07/2008 EN Edition 2.8 Disabling the compressed air supply and discharging the pressure
75
2.7.2 Residual voltages and discharge times after switching off at the main switch
2
2
CAUTION 2
To avoid losing data, assess the following criteria before switching off your machine (apart from in
emergencies):
Has the machine finished transmitting machine, setup and panel data?
Has the machine finished processing the PCB?
Has the machine completed the run-up phase?
2.8 Disabling the compressed air supply and discharg-
ing the pressure
The compressed air working pressure of the machine is set to 0.51 ± 0.01 MPa (5.1 ± 0.1 bar).
The position of the compressed air unit is indicated by Fig. 2.8 - 1
. The compressed air supply to
the machine can be interrupted using the shutoff valve (item 1 in Fig. 2.8 - 1
).
Use the machine key to release the cover lock.
Lift off the cover (see Fig. 2.8 - 1
).
Turn the lever on the shutoff valve (item 1 in Fig. 2.8 - 1
) from the vertical to the horizontal
position.
Watch the working pressure gauge (item 4 in Fig. 2.8 - 1
). When the machine is switched on,
the pressure discharges to 0 MPa (0 bar) within 1 minute.
CAUTION
When the machine is switched on, do not use the stop valve to interrupt the compressed air sup-
ply for more than 30 minutes. If you need to shut off the pneumatic system for longer in order to
carry out preventive maintenance or servicing work, you must switch the machine off at the main
switch and disconnect it from the power supply.
Pin X14 and terminal P150 (X1)
measured to X15 (GND)
Residual voltages when
main power switch is off Discharge times
X14 < 60 VDC < 4 s
P150 (X1) < 60 VDC < 1 s
2 Operational safety User manual SIPLACE D4
2.8 Disabling the compressed air supply and discharging the pressure From software version SR.605.xx 07/2008 EN Edition
76
Fig. 2.8 - 1 Compressed air unit on the machine
(1) Stop valve
(2) Manometer for the input pressure
Desired pressure: 0.55 - 1.0 MPa, 5.5 - 10 bar (display range: 0 - 1.2 MPa, 0 - 12 bar)
(3) Compressed air filter
(4) Manometer for the gantry distributor supply pressure
Desired pressure: 0.51 ± 0.01 MPa, 5.1 ± 0.1 bar (display range 0 - 1.2 MPa, 0 - 12 bar)
(5) Manometer for the bulk case feeder modules supply pressure
Desired pressure: 0.25 ± 0.05 MPa, 2.5 ± 0.5 bar (display range 0 - 0.6 MPa, 0 - 6 bar)
WARNING
NEVER detach compressed air lines while they are still pressurized. Risk of injury. 2