00196803-02_VD_SIPLACE_Pro_9.3_DE EN.pdf - 第50页
Software Version sbeschreibun g Programmiersy stem SIPLACE Pro 9.3 Software Version Description Programming Sys tem SIPLAC E Pro 9.3 50 5.3.15 Nozz le Report Using the Nozzle re ports, it is possible to create a doc umen…

Software Versionsbeschreibung Programmiersystem SIPLACE Pro 9.3
Software Version Description Programming System SIPLACE Pro 9.3
49
8. The job is sent to the station after a successful integrity and license check.
Notes
The feature requires station software 705. Earlier software versions (605 or 703) were
not tested.
The features "Random Setup" and "Alternative Component" cannot be combined on
one single line.
For further information on this feature and its restrictions please see the user manual
“SIPLACE Random Setup“ on the product CD.
5.3.9 Teaching of Placement Positions
From station software 705, placement position offsets (X, Y and angle) can be taught at the station
and uploaded to SIPLACE Pro.
In the PCB editor, the placement positions to be taught have to be marked. The taught placement
position offsets are taken into account when supplying data to stations with prior software versions
(e.g. station software version 40x and 50x). A change in the placement position offsets is distributed to
other stations in the line that place the placement position of the same name.
Notes
The SIPLACE Pro user "Service" has to have writing access to placement lists.
In addition, the user logged into the station has to have writing access to the placement
list that contains the uploaded placement position.
5.3.10 Split Table at Track and SiCluster Professional
Besides optimizing split tables in SiCluster Professional it is also possible to use this option for the
cluster jobs and their Result Jobs.
5.3.11 Whispering of Barcode Information
Note
The feature can be activated with the "Whispering of Barcodes" license.
5.3.12 Long Board Option
Note
The feature can be activated with the "Long Board Option" license.
5.3.13 Integrity Check for Multiple Jobs
Similar to the Multi Job Optimization and the Multi Cluster Job Optimization there is the Multi Integrity
Check in the Optimizer toolkit. From the structure tree of the recipes the recipes to be checked are
added to a recipe list and optimized in the desired sequence and according to the settings.
At the same time, the optimization starts an adjustable number of processes and thus utilizes the
present multi core processors.
5.3.14 Query Tool
The underlined results of queries can be clicked on. The corresponding object is opened in SIPLACE
Pro Desk.
Software Versionsbeschreibung Programmiersystem SIPLACE Pro 9.3
Software Version Description Programming System SIPLACE Pro 9.3
50
5.3.15 Nozzle Report
Using the Nozzle reports, it is possible to create a documentation of a single nozzle and a list of
nozzles.
In the list of several nozzles up to ten attributes can be selected. The nozzle attributes to be shown
can be changed in the report details.
The report can be started via the context menu in the structure view.
5.3.16 Warnings as Errors
All warning messages of the Optimizer can be upgraded to an error or downgraded to a warning
again.

Software Versionsbeschreibung Programmiersystem SIPLACE Pro 9.3
Software Version Description Programming System SIPLACE Pro 9.3
51
6 Limitations
6.1 Restrictions
A complete Line computer data import of big customer data may take long (up to several hours),
depending on the amount of data and the computer system used.
Linear 10 and 15 reserves cannot be combined on the same linear feeder.
When importing setup files (.rt files) from the line computer, you cannot import more than one tray
per level. In case you import more than one tray per level, you have to create them manually in
SIPLACE Pro.
Note:
SIPLACE Pro object names (e.g., Recipe) must not exceed 125 ASCII characters
(including folder names). If the station software is 504 or older, these names are
shortened to 20 ASCII characters.
In a multi-client scenario, when different users optimize the same job at the same time, the last
successfully finished job will overwrite all associated recipes.
The operator has to put Manual Tray Carriers (Carrier 30, Carrier 51, Carrier X and Carrier SX)
manually in the initial setup.
If you work with a reduced acceleration for a component shape you have a special case and the
accuracy of 5% of the simulated Optimizer production time is not kept.
The Optimizer does not check if the tray size is bigger than the carrier.
The WPC can take up to 10 different component types per level. This does not apply to machines
from station SW version 70x upwards.
6.2 Known Issues/Problems (General)
Station-wise Download
When the line control server is rebooted, station-wise downloading will be cancelled. After
rebooting, you will need to perform a complete line download to restart production.
Station-wise downloading supports setup changes in asynchronous dual operation only with the
same definition at both lanes.
Station-wise downloading supports synchronous dual operation as of station SW version 704.
Export of Restrictions from SIPLACE Pro to the Line Computer
It is possible to export restrictions from SIPLACE Pro 2.0 Service Pack 1 onwards to the line
computer. Because of data structure differences line computer and SIPLACE Pro behave differently.
The two main differences are:
1. The line computer forces you to select a specific recipe and the created restriction is based on this
recipe only.
In SIPLACE Pro, however, you are free to use every restriction with any recipe in any job. The line
computer cannot identify to which recipe the restriction belongs and therefore the line computer
does not know where to save the restriction.