00198371-01_UM_SWS-EN - 第103页
User manual SIPLACE Wafer System (SWS) 5 SWS tasks Edition 04/2018 5.10 Switching on and off 103 5.10 Switching on and off 5.10.1 Switching the SWS on First switch on all existing SW S modules for the SIPLACE CA4 V2. T…

5 SWS tasks User manual SIPLACE Wafer System (SWS)
5.9 Controls and displays Edition 04/2018
102
5.9.3 Ergonomic arrangement of controls
Fig. 5.9 - 1, page 100 provides an overview of the position of the controls. They are subdivided
into the following groups:
– LCD touchscreen
– Keyboard
– EMERGENCY STOP button
– Main switch
5.9.3.1 Controls on the control panels
The two operator panel have identical control functions.
Monitor and keyboard,
The SIPLACE Wafer System has a monitor and keyboard attached.
Main switch
The main power switch is part of the power module. It is located here because it is only needed
for servicing and preventive maintenance work and is therefore not subject to frequent use.
User manual SIPLACE Wafer System (SWS) 5 SWS tasks
Edition 04/2018 5.10 Switching on and off
103
5.10 Switching on and off
5.10.1 Switching the SWS on
First switch on all existing SWS modules for the SIPLACE CA4 V2.
The modules are starting up. As long as the placement machine is not yet switched on, an
error message will be displayed on the screen of the SWS module, which points out that
the safety circuit is not closed. 5
Switch the placement machine on.
The station computer will start. 5
As soon as the placement machine has been started up and the start button has been pressed,
the error message regarding the not-closed safety circuit vanishes from the SWS monitors. Initial-
ize the SWS module.
When the initializing process is completed, the SWSs are ready to operate and in standby.
5.10.2 Switching the SWS off
Switching off the SWS
Complete all processes running at the SWS modules.
Select Settings -> Shut down machine.
SWS GUI and Linux are shut down properly. 5
Switch off the SWS at the main switch.
Repeat this, if necessary, for each other SWS module.

5 SWS tasks User manual SIPLACE Wafer System (SWS)
5.11 The user interface Edition 04/2018
104
5.11 The user interface
The SWS GUI is the user interface for the SIPLACE Wafer System (SWS). After starting the SI-
PLACE Wafer System, the SWS GUI main view will automatically open.
5
Fig. 5.11 - 1 Main view of SWS GUI
Legend
(1) Help system
(2) Function toolbar
(3) Task and display section
For more information about the SWS GUI, refer to the context-sensitive Online Help.
Click on the Help System (1) icon to open the context-sensitive Online Help function.
Use the list of contents, index and the search function to view the contents of the Online Help.
(3)
(2)
(1)