Page 7-10 Recognition Unit Maintenance 7-8-1 Recognition Unit Update This section describes updating the recognition system. Copy the recognition system from the floppy disk with recognition system to be upgraded to RAM,…

Page 7-9
MACHINE
ADJUSTMENT
7
7-8 Recognition Unit Maintenance
All recognition process can be checked. ( Appendix A)
Ref no
Current setting value of reference No. is checked and changed. It can be changed by .
Threshold
Current setting value of binary threshold can be checked and changed. It can be changed by
.
Teach scrn
When reference No. set now is block, teaching screen is displayed.
Area
Area is set as a test. Area is changed by . Pressing Complete sets the area.
Recog
Recognition is carried out under the condition set now.
Error scrn
Recognition error screen occurred by now can be checked to maximum of 110 screens. Screen
can be changed by .
Scale
Scale is displayed on the screen.
Cross line
Cross hair is displayed on the recognition screen. Position is changed by .
Ver, Memory
Current version of recognition system and recognition ROM is displayed on the recognition
system.
Recognition system can be updated.
Reset
In selecting “Area,” “Error screen,” and “Cross line,” each information can be reset.
In selecting “Ref No.,” “Threshold,” “Area,” and “Cross line,” each changing rate can be adjusted.
Img print
Recognition image displayed on the touch panel can be printed.
Recog unit
update
3Y3C-E-EMD07-A01-00
Cursor resps

Page 7-10
Recognition Unit Maintenance
7-8-1 Recognition Unit Update
This section describes updating the recognition system.
Copy the recognition system from the floppy disk with recognition system to be upgraded to RAM,
and after comparing (inspecting by reading) the system of floppy disk with that of RAM, the system
is written to the memory if no trouble is found.
<Description of Items>
ROM version : Current recognition ROM version
System version : Version of recognition system to upload
All blocks : Current recognition system volume
Transferring blocks : Transferred recognition system volume
∗ Refer to “Chapter 4 UPDATING” in the Maintenance Manual for the details.
3Y3C-E-EMD07-A01-01

Page 8-1
3Y3C-E-EMD08-A01-00
Chapter 8
MACHINE SETTING
MACHINE SETTING
Machine setting
That state of machine independent of production data can be set.
8-1 Adjustment switch
Condition of producing can be temporally changed for adjustment.
8-2 Pickup posn learning
Corrected value by pickup position learning in producing can be checked for each feeder address.
8-3 Bad head
Each head and nozzle for it can be checked.
8-4 Time set
Time for machine can be set.
8-5 Speed set
The speed in producing can be temporally changed for adjustment.
8-6 Customizing Operator mode
You can set the functions which were available only in the engineer mode, to us in the operator