8.11 Analysis - Common Error List
130 Technical Training FSE SIPLACE TX-Series 01/2018
8.11 Analysis - Common Error List
Code Error Description Possible Cause Action
30447
30451
30456
30256
30262
●
Communication on GCU-
GCU fast drive bus inter-
rupted
●
Specified CAN bus is
switched off
●
Secondary CAN bus is off
●
Cannot initialize CAN
hardware
●
Cannot initialize CAN inter-
face
●
Problem with cable
connection
●
Problem with CIN
●
Problem with certain
content/board in the
CAN circuit
●
Defective MGCU
●
Defect adapter/HCU
●
Check cable con-
nection
●
Restart the
machine
●
Check the status
and switch setting
on the CIN
●
Check and redown-
load firmware of
the CAN interface
●
Check status / in-
dication on the
board related in
CAN circuit
●
Check status / in-
dication of MGCU/
HMCU
●
Replace adapter/
HCU
37752
●
The LED test of the cam-
era illumination failed
●
No image captured from
camera
●
Power for illumination
of camera failed
●
LED failed but camera
can be operated
●
Problem with camera
GigE
●
Problem of cable GigE
●
Check relevant cir-
cuit of power for il-
lumination
●
Check output relev-
ant power supply
(PS)
●
Check the function-
ality of camera
●
Check connection
of the GigE cable
33378
33520
33606
33331
●
Camera cannot be ad-
dressed
●
Board camera cannot be
addressed
●
Image capture from cam-
era canceled
●
Signal path between
PC and camera inter-
rupted
●
Problem with camera
●
Check cable con-
nection on BoxPc
●
Check the coax
cable connection
and trailing cable
connector
●
Check the camera
cable
●
Check the camera
and replace if ne-
cessary
30365
30572
●
Moving the axis is not per-
mitted, Z Axis is not in a
safe position
●
Incorrect time sequence
when moving Star and Z
Axis
●
Sporadic communica-
tion error for axis con-
trol sequence
●
Permitted overlap re-
gion of Star and Z
been reached
●
Perform head axis
reference run
●
Check the head
and axis
●
Perform overall ref-
erence run
●
If certain segment
defective, replace it

8 Control and Communication
8.12 Excercise: Control and Communication
Technical Training FSE SIPLACE TX-Series 01/2018 131
8.12 Excercise: Control and Communication
1. Which of the following statements is true regarding TX communication system?
A CIN Box is instead of communication board (CAN bus card).
B Vision GigE system is instead of vision hotlink system.
C There are three different bus systems, CAN bus, Gantry CAN bus and FDB.
D All of the above.
2. Which parts do not communicate with the BOXPC via the CAN bus system in TX?
A CIN-Box.
B Conveyor controller (TSP).
C FCU (Feeder control unit), MHCU and MGCU.
D I/O unit (input/ output module).
3. Which of the following statements is true regarding parts exchange?
A No setting required after exchanging a MGCU.
B No setting required after exchanging a MHCU.
C No setting required after exchanging a FCU.
D No setting required after exchanging a CIN-Box.
4. CIN-Box is connected to BoxPC with CAT5 cable, and uses CAN bus cable to commu-
nicate with subsystem.
True …………………………………………………………………………………………………
False …………………………………………………………………………………………………
5. List all of subsystems which are controlled by CAN bus.
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
6. List the parts which are controlled by FCU.
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………

8 Control and Communication
Room for Your Sketches and Notes
132 Technical Training FSE SIPLACE TX-Series 01/2018
Room for Your Sketches and Notes