00198171-02_Technical_Training_FSE_TX-Series_EN - 第92页
7 Power Supply 7.3 Voltage Overview Block diagrams 92 Technical Training FSE SIPLACE TX-Series 01/2018 7.3.4 42 VDC Switched and Unswitched The following diagram illustrates the generation of the 42V intermediate circuit…

7 Power Supply
7.3 Voltage Overview Block diagrams
Technical Training FSE SIPLACE TX-Series 01/2018 91
7.3.3 160 V Intermediate Circuit Voltage for Head Axes
The following diagram illustrates the generation of the 160V intermediate circuit current for the
head axes.
*S1 Switch for Intermediate voltage Z Axis, 160V for CPP, 42V for C&P20 P
●
The 160VDC voltage (intermediate circuit) for head axis is not managed via the backup bat-
tery as no energy compensation problems occur here.
●
This voltage runs directly from the power pack PS1 via the backup battery CAP (without func-
tion) to the CSB and is switched there to the pre/discharge board.
●
The head axis voltage is then run via the FDB assembly, protected by fuses there and sent on
to the heads.
Voltage Type Fuse Usage
160 VDC Switched F19 Star Motor gantry 1
160 VDC Switched F19 Z Motor CPP gantry 1
160 VDC Switched F20 Star Motor gantry 2
160 VDC Switched F20 Z Motor CPP gantry 2

7 Power Supply
7.3 Voltage Overview Block diagrams
92 Technical Training FSE SIPLACE TX-Series 01/2018
7.3.4 42 VDC Switched and Unswitched
The following diagram illustrates the generation of the 42V intermediate circuit.
Voltage Type Fuse Usage
42 VDC Unswitched F14 Z Motor CP20 gantry 1
42 VDC Unswitched F15 Z Motor CP20 gantry 2
42 VDC Unswitched F21 Camera illumination (Component & PCB) both
gantry
42 VDC Unswitched F21 Illumination for stationary camera
42 VDC Switched F16 Drive motor for conveyor

7 Power Supply
7.3 Voltage Overview Block diagrams
Technical Training FSE SIPLACE TX-Series 01/2018 93
7.3.5 24 VDC Switched and Unswitched
Fuses 1-3 and 5 -10
Voltage Type Fuse Usage
24 VDC Unswitched F1 Voltage MGCU1
24 VDC Unswitched F2 Voltage MGCU2
24 VDC Unswitched F3 Voltage for extern service/blower (Reserve I/O &
optional)
24 VDC Unswitched F5 Voltage control computer (PC)
24 VDC Unswitched F6 Voltage monitors / CIN (Can interface)/ PC (op-
tional)
24 VDC Unswitched F7 Voltage conveyor control (TSP-420M) has an in-
ternal micro fuse
24 VDC Unswitched F8 Not Used
24 VDC Unswitched F9 Not Used
24 VDC Unswitched F10 For internal diagnostic of power supply unit