DECAN_S1_Operation_EN.pdf - 第79页

Ch e ck o th e r s and r e plac e e xhaus t e d part s Chap ter 6 Nex t Generation, Multi- Funct ional Placer DE CAN S 1 Ope ra tio n Han db oo k 6-6 This Chapter describes the items for which care must be exercised whil…

100%1 / 94
Check others and replace exhausted parts
Chapter 6
Next Generation, Multi-Functional Placer
DECAN S1 Operation Handbook
6-5
This Chapter describes the items for which care must be exercised while
using thetape feeder as well as the method to take measures when
parts are exhausted.
Checking Feeder > Checking locker
Checking Feeder
5. Checking locker
Check Points
After mounting the part reel on the feeder, make sure the locker
is properly locked.
Caution
If the tape guide and the locker are not locked properly, it may
collide with the head during operation.
Check others and replace exhausted parts
Chapter 6
Next Generation, Multi-Functional Placer
DECAN S1 Operation Handbook
6-6
This Chapter describes the items for which care must be exercised while
using thetape feeder as well as the method to take measures when
parts are exhausted.
Checking Feeder > Tape Guide Vinyl Setting (Electrically Driven)
Checking Feeder
Check others and replace exhausted parts
6. Tape Guide Vinyl Setting (Electrically Driven)
1. Install tape at the upper cover of the feeder
Vinyl tape is installed normally
Vinyl tape is curled
Caution
Exercise care so that the vinyl tape is not curled when setting the
tape at the front/rear slit
Check others and replace exhausted parts
Chapter 6
Next Generation, Multi-Functional Placer
DECAN S1 Operation Handbook
6-7
This Chapter describes the items for which care must be exercised while
using thetape feeder as well as the method to take measures when
parts are exhausted.
Checking Feeder > Tape Guide Vinyl Setting (Electrically Driven)
Checking Feeder
7. Tape Guide Vinyl Setting (Electrically Driven)
1. Install the tape through the front/rear slit
Install the tape through the rear slit(GENERAL)
Install the tape through the front slit(OPTION)
Caution
In the case of 0402 parts, the tape must be installed in the
feeder through the front slit.
When installing the tape for 0603 parts through the front slit,
use parts that are free of static electricity.
If a part has static electricity, it may cause a pickup error due to
static electricity during its supply.